Implant-based factor as possible risk for peri-implantitis
(2019-01-01)
Peri-implantitis is currently a topic of major interest in implantology. Considered one of the main reasons of late implant failure, there is an emerged concern whether implant characteristics could trigger inflammatory ...
Influence of the Connector and Implant Design on the Implant-Tooth-Connected Prostheses
(Wiley-Blackwell, 2010-01-01)
Purpose:The purpose of this study was to evaluate stress transfer patterns between implant-tooth-connected prostheses comparing rigid and semirigid connectors and internal and external hexagon implants.Materials and ...
Influence of Implant Design on the Biomechanical Environment of Immediately Placed Implants: Computed Tomography-Based Nonlinear Three-Dimensional Finite Element Analysis
(Quintessence Publishing Co Inc, 2011-11-01)
Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants. Materials and Methods: Computed tomography (CT)-based finite element models comprising a ...
Influence of implant design on the biomechanical environment of immediately placed implants: Computed tomography-based nonlinear three-dimensional finite element analysis
(2011-01-01)
Purpose: To evaluate the influence of different implant designs on the biomechanical environment of immediately placed implants. Materials and Methods: Computed tomography (CT) -based finite element models comprising a ...
Effects of implant thread geometry on percentage of osseointegration and resistance to reverse torque in the tibia of rabbits
(Amer Acad PeriodontologyChicagoEUA, 2004)
Comparative Microstrain Study of Internal Hexagon and Plateau Design of Short Implants Under Vertical Loading
(Lippincott Williams & Wilkins, 2016-02-01)
Purpose: To quantify microstrain development during axial loading using strain gauge analysis for short implants, varying the type of fixture-abutment joint and thread design. Materials and Methods: An internal hexagon ...
Stress distribution in implant-supported prosthesis with external and internal implant-abutment connections
(2013-03-01)
Objective. This study aimed to investigate the stress distribution in screwed implant-supported prostheses with different implant-abutment connections by using a photoelastic analysis. Materials and methods. Four photoelastic ...
Evaluation of primary stability in modified implants: Analysis by resonance frequency and insertion torque
(2018-06-01)
Background: Changes in the macrogeometry of dental implants are known to influence primary stability and the osseointegration process. Purpose: The purpose of the present in vitro study was to evaluate the mechanical ...