Buscar
Mostrando ítems 1-10 de 26
Evaluation of distribution system losses due to load unbalance
(2005-01-01)
Distribution network losses can vary significantly depending on the load unbalance. Here, an analysis of distribution system losses is presented that considers load unbalance and the effect of explicitly represented neutral ...
Load compensation in four-wire electrical power systems
(IEEE, 2000-01-01)
This work describes a methodology for power factor control and correction of the unbalanced currents in four-wire electric circuits. The methodology is based on the insertion of two compensation networks, one wye-grounded ...
Using MatLab-Simulink for simulating load compensation in four-wire electrical power systems
(2004-12-01)
This work describes a method of power factor control and correction of the unbalanced currents in four-wire electrical circuits. This method is based on the insertion of two compensation networks, one wye-grounded neutral ...
Design of Static VAr Compensator using a General Reactive Energy Definition
(Ieee, 2013-01-01)
This paper describes a methodology to design Static VAr Compensators (SVC) using the reactive energy definition from Conservative Power Theory. Application of this methodology is presented through simulations of local and ...
Design of static VAr compensator using a general reactive energy definition
(2013-01-01)
This paper describes a methodology to design Static V Ar Compensators (SVC) using the reactive energy definition from Conservative Power Theory. Application of this methodology is presented through simulations of local and ...
A Symmetrical Cascaded H-Bridge Multilevel Inverter Used as Shunt Active Power Filter for Ideal and Deteriorated Voltage Conditions
(Ieee, 2016-01-01)
This paper discusses the use of a Cascaded H-bridge Multilevel Inverter (CHMI) as shunt active power filter (SAPF) for selective disturbing currents compensation. The main feature of the proposed approach is the use of ...
A symmetrical Cascaded H-bridge Multilevel Inverter used as shunt active power filter for ideal and deteriorated voltage conditions
(2016-11-02)
This paper discusses the use of a Cascaded H-bridge Multilevel Inverter (CHMI) as shunt active power filter (SAPF) for selective disturbing currents compensation. The main feature of the proposed approach is the use of ...
Application of Conservative Power Theory to load and line characterization and revenue metering
(2012-12-14)
This paper proposes a set of performance factors for load characterization and revenue metering. They are based on the Conservative Power Theory, and each of them relates to a specific load non-ideality (unbalance, reactivity, ...
Possible shunt compensation strategies based on conservative power theory
(2010-08-23)
Considering the Conservative Power Theory (CPT), this paper proposes some novel compensation strategies for shunt passive or active devices. The CPT current decompositions result in several current terms, which are associated ...
A new method for real time computation of power quality indices based on instantaneous space phasors
(2004-12-01)
One of the important issues about using renewable energy is the integration of dispersed generation in the distribution networks. Previous experience has shown that the integration of dispersed generation can improve voltage ...