dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorCarvalho, Adriana Oliveira
dc.creatorAyres, Ana Paulaalmeida
dc.creatorAlmeida, LetÍcia Cunhaamaral Gonzaga de
dc.creatorBriso, André Luiz Fraga
dc.creatorRueggeberg, Frederick Allen
dc.creatorGiannini, Marcelo
dc.date2016-01-28T16:55:27Z
dc.date2016-10-25T21:28:15Z
dc.date2016-01-28T16:55:27Z
dc.date2016-10-25T21:28:15Z
dc.date2015
dc.date.accessioned2017-04-06T09:48:15Z
dc.date.available2017-04-06T09:48:15Z
dc.identifierEuropean Journal of Dentistry, v. 9, n. 2, p. 246-250, 2015.
dc.identifier1305-7456
dc.identifierhttp://hdl.handle.net/11449/133518
dc.identifierhttp://acervodigital.unesp.br/handle/11449/133518
dc.identifier10.4103/1305-7456.156845
dc.identifier5761956467234702
dc.identifierhttp://dx.doi.org/10.4103/1305-7456.156845
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/944048
dc.descriptionObjective: This study evaluated the effects of carbamide peroxide and hydrogen peroxide on the biaxial flexural strength and flexural modulus of bovine dentin. Materials and Methods: Thirty coronal dentin disks (0.5 mm thick × 6.0 mm diameter) were prepared from bovine teeth. The disks were randomly divided into three groups (n=10): A control group (unbleached), a group bleached with 10% carbamide peroxide (8 h at 37°C), and a group bleached with 38% hydrogen peroxide (three 10 min applications at 37°C). The specimens were tested in a biaxial flexural apparatus held in a universal testing machine at 1.27 mm/min until failure occurred, and the biaxial mechanical properties were calculated. For each test parameter, the data were statistically analyzed by Fisher's PLSD test (predetermined a = 0.05). Results: The group bleached with 38% hydrogen peroxide demonstrated significantly lower flexural strength than the unbleached control group. Hydrogen peroxide treatment resulted in a significantly lower flexural modulus compared with the control group and with carbamide peroxide bleaching. Conclusion: Exposure of dentin to hydrogen peroxide significantly reduced both the flexural strength and the flexural modulus compared with the no-treatment control, whereas exposure to carbamide peroxide did not significantly affect either parameter.
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.descriptionFundação Amparo à Pesquisa Estado de São Paulo (FAPESP)
dc.languageeng
dc.relationEuropean Journal of Dentistry
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectBiaxial flexural strength
dc.subjectBleaching
dc.subjectCarbamide peroxide
dc.subjectDentin
dc.subjectFlexural modulus
dc.subjectHydrogen peroxide
dc.titleEffect of peroxide bleaching on the biaxial flexural strength and modulus of bovine dentin
dc.typeOtro


Este ítem pertenece a la siguiente institución