Otro
Evaluation of glucose biosensors based on Prussian Blue and lyophilised, crystalline and cross-linked glucose oxidases (CLEC (R))
Registro en:
Talanta. Amsterdam: Elsevier B.V., v. 54, n. 5, p. 963-974, 2001.
0039-9140
10.1016/S0039-9140(01)00367-8
WOS:000169852200020
2-s2.0-0035927844
Autor
Mattos, Ivanildo Luiz de
Lukachova, Lilia V.
Gorton, Lo
Laurell, Thomas
Karyakin, Arkady A.
Resumen
Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some common interfering species (ascorbic acid, acetaminophen and uric acid). The operational stability of the biosensors was evaluated by applying a steady potential of -50 mV versus Ag/AgCl to the glucose biosensor and injecting standard solutions of hydrogen peroxide and glucose (50 muM and 1.0 mM, respectively, in phosphate buffer) for at least 5 h in a flow-injection system. Scanning electron microscopy was used for visualisation of the Prussian Blue redox catalyst and in the presence of the different GOx preparations on the electrode surface. (C) 2001 Elsevier B.V. B.V. All rights reserved.
Materias
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Daytime variations in glucose tolerance in people with impaired glucose tolerance
Santos, Maria Luiza dos; Aragon, Flávio F.; Padovani, Carlos R.; Pimenta, Walkyria P. -
Daytime variations in glucose tolerance in people with impaired glucose tolerance
Universidade Estadual Paulista (Unesp) (2006-12-01)To determine whether glucose tolerance varies throughout the day in people with impaired glucose tolerance (IGT). We studied 15 healthy IGT, and 18 matched normal glucose tolerant (NGT) individuals. Blood samples were taken ... -
Daytime variations in glucose tolerance in people with impaired glucose tolerance
Universidade Estadual Paulista (Unesp) (2006-12-01)To determine whether glucose tolerance varies throughout the day in people with impaired glucose tolerance (IGT). We studied 15 healthy IGT, and 18 matched normal glucose tolerant (NGT) individuals. Blood samples were taken ...