dc.description.abstractEl ascenso del agua subsuperficial ha generado un desequilibrio entre la recarga y descarga del acuífero, que ya es notorio en los últimos años, en especial en Huancaquito Alto – Sector La Pampa. Por esta razón, el objetivo del presente proyecto es diseñar un sistema de drenaje. Se han realizado estudios de drenaje, tales como levantamiento topográfico, estudios físicos de suelo, obteniendo una textura predomínate de franco arenoso y análisis químico para determinar, la categoria de salinidad que se encontró 0,15 a 0,45 dS/m y un pH de 7,68 a 8,45 de grado moderadamente básico a ligeramente alcalino, mientras que en el estudio físico químico del agua se obtuvo una conductividad eléctrica del agua subterránea es mayor que el de riego, con un pH entre ligeramente básico y ligeramente alcalino. Se calculó la conductividad hidráulica 0,55 m/día, por el método del barreno invertido, también con la instalación de fretimetros, para el monitoreo del nivel freático, obteniendo una altura mínima de 0,52 metros referente al nivel del suelo, con los datos obtenidos se realizaron planos de textura, Conductividad eléctrica, curvas de isoprofundidad, hisoypsas y dirección de flujo. Se logró determinar el distanciamiento entre drene a instalar es de 22,46 m y descarga de drenes 0,00091 m/día, por un tiempo de 3 días, con estos parámetros se obtuvo drenes laterales y un dren colector que desemboca en un lateral de dren, este sistema de drenaje a instalar tuvo un costo de S/ 190 854,46 Soles.
dc.description.abstractABSTRACT The rise of subsurface water has generated an imbalance between the recharge and discharge of the aquifer, which is already nototious in recent years, especially in Huancaquito Alto – La Pampa sector, for this reason, the objective of this Project is to design a drainage system. Drainage studies have been carried out, such as topographical surveys, physical studies of the soil, obtaining a predominantly sandy loam texture and chemical analysis to determine the range of salinity found from 0,15 to 0,45 dS/m and a Ph from 7,68 to 8,45 from a moderately basic to slightly alkaline degree, while in the physical chemical study of the water, and electrical conductivity of the groundwater was obtained that is greater than that of irrigation, with a pH between slightly between slightly basic and slightly alkaline. Hydraulic conductivity was calculated at 0,55 m/day, by the inverted hole method, also with the installation of freatimeters, for monitoring the water table, abtaining a mínimum height of 0,52 meters refering to ground level, with the data obtained texture plans, electrical conductivity, isodepth curves, hysoypsas and flow direction were made. It was posible to dtermine the distance between the drain to be installed is 22,46 meters and drain discharge 0.00091 m/day, for a period of 3 days, with these parameters lateral and lateral drains were obtained, a collector drain, this drainage system to be installed has a cost of S/ 210 087,09 soles.
dc.languagees
dc.publisherUniversidad Nacional de Trujillo
dc.publisherPE
dc.rightshttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectAgricultura
dc.subjectAgua subterránea
dc.subjectSalinidad
dc.titleDiseño de un sistema de drenaje en 5,77 ha parcela N° 01459 - Sector la Pampa Huancaquito Alto –Virú – La Libertad
dc.typeinfo:eu-repo/semantics/bachelorThesis