dc.contributorHuerta Campos, Carlos Alberto
dc.creatorRamón Quiroz, Isaías Lucas
dc.creatorAguirre Oré, Rubén Darío Martin
dc.date.accessioned2022-08-16T19:37:37Z
dc.date.accessioned2024-05-07T03:09:48Z
dc.date.available2022-08-16T19:37:37Z
dc.date.available2024-05-07T03:09:48Z
dc.date.created2022-08-16T19:37:37Z
dc.date.issued2021-05-25
dc.identifierhttp://hdl.handle.net/10757/660654
dc.identifier0000 0001 2196 144X
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/9329576
dc.description.abstractLa búsqueda por obtener un concreto de baja permeabilidad en su estado endurecido, haciendo uso adicional de algún componente que provenga de manera fácil, útil y sobre todo económico, ha motivado la siguiente investigación haciendo uso del vidrio sódico – cálcico. Este es un vidrio común y corriente que se encuentra a diario, así como en los lugares de reciclaje. Asimismo, aprovechando que este material contiene sílice, ayudaría significativamente al cemento. El presente trabajo de investigación tiene como objetivo principal analizar el comportamiento del concreto mediante el reemplazo parcial del cemento por vidrio reciclado molido (VRM) en porcentajes de 5%, 10% y 15% para obtener una resistencia de 210 kg/cm2, con la finalidad de determinar la profundidad de penetración de agua bajo presión, a través de la Norma Europea EN 12390-8. Para los objetivos mencionados, se elaboró 48 probetas cilíndricas de concreto para ensayos de compresión, 16 vigas de concreto para ensayos de flexión, 12 cilindros de concreto para ensayos de tracción y 12 prismas de concreto para ensayos de permeabilidad y absorción. Los resultados de los diseños respecto a la profundidad de penetración del agua bajo presión fueron de 76.83 mm, 74.20 mm, 72.23 mm y 84.75 mm, para adición de vidrio molido del 0%, 5%, 10% y 15% respectivamente. Se evidencian tras los diferentes análisis que el porcentaje óptimo que reduce la permeabilidad del concreto es la adición del 5% de vidrio molido en reemplazo parcial del cemento.
dc.description.abstractThe search to obtain a low permeability concrete in its hardened state, making additional use of some component that comes in an easy, useful and above all economical way, has motivated the following research making use of sodium-calcium glass, which is glass common and current that we find daily. In turn, they are in recycling places and taking advantage of the fact that this material contains silica would significantly help cement. The main objective of this research work is to analyze the behavior of concrete by partially replacing cement with ground recycled glass (VRM) in percentages of 5%, 10% and 15% to obtain a resistance of 210 kg / cm2, with the purpose of determining the penetration depth of water under pressure, through the European Standard EN 12390-8. For the purposes mentioned, 48 ​​cylindrical concrete specimens were prepared for compression tests, 16 concrete beams for flexural tests, 12 concrete cylinders for tensile tests and 12 concrete prisms for permeability and absorption tests. The results of the designs regarding the depth of penetration of water under pressure were 76.83 mm, 74.20 mm, 72.23 mm and 84.75 mm, for the addition of ground glass of 0%, 5%, 10% and 15% respectively. It is evident after the different analyzes that the optimal percentage that reduces the permeability of the concrete is the addition of 5% of ground glass in partial replacement of the cement.
dc.languagespa
dc.publisherUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.publisherPE
dc.rightshttp://creativecommons.org/licenses/by-nc-sa/4.0/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.rightsAttribution-NonCommercial-ShareAlike 4.0 International
dc.sourceUniversidad Peruana de Ciencias Aplicadas (UPC)
dc.sourceRepositorio Académico - UPC
dc.subjectConcreto de baja permeabilidad
dc.subjectReemplazo parcial de vidrio molido
dc.subjectEnsayos a la compresión
dc.subjectFlexión y permeabilidad
dc.subjectAbsorción del concreto
dc.subjectLow permeability concrete
dc.subjectPartial replacement of ground glass
dc.subjectCompression
dc.subjectFlex and permeability tests
dc.subjectConcrete absorption
dc.titleAnálisis de la permeabilidad en el concreto, con adiciones de vidrio reciclado molido en reemplazo parcial del cemento en Lima Metropolitana
dc.typeinfo:eu-repo/semantics/bachelorThesis


Este ítem pertenece a la siguiente institución