Method for determining dissolved oxygen in water using the MnIII-EDTA complex

dc.contributorNeves, Antônio Augusto
dc.contributorhttp://lattes.cnpq.br/4891022029555578
dc.contributorOliveira, André Fernando de
dc.contributorQueiroz, Maria Eliana Lopes Ribeiro de
dc.creatorFerraz, Camila Jerônimo
dc.date2022-08-01T11:39:57Z
dc.date2022-08-01T11:39:57Z
dc.date2020-03-12
dc.date.accessioned2023-09-27T20:53:33Z
dc.date.available2023-09-27T20:53:33Z
dc.identifierFERRAZ, Camila Jerônimo. Método para determinação de oxigênio dissolvido em águas utilizando complexo Mn III-EDTA. 2020. 78 f. Dissertação (Mestrado em Agroquímica) - Universidade Federal de Viçosa, Viçosa. 2020.
dc.identifierhttps://locus.ufv.br//handle/123456789/29470
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8950293
dc.descriptionO objetivo deste trabalho foi desenvolver um método para análise de oxigênio dissolvido em água a partir da formação do complexo MnIII-EDTA por meio da oxidação de Mn (II) pelo oxigênio presente em solução. O oxigênio dissolvido é considerado um dos constituintes mais relevantes dos recursos hídricos, por estar diretamente relacionado à gama de organismos capazes de sobreviver (aeróbios e anaeróbios). As principais formas de medir a concentração de oxigênio em solução são os métodos amperométricos, uso de sensores ópticos baseados em fluorescência e o iodométrico. Embora existam diferentes dispositivos para cada uma dessas técnicas, seu uso depende das características do ambiente em que serão utilizados. Nesses métodos as condições devem ser otimizadas e a calibração realizada, com exceção do iodométrico. Este apesar de ser considerado padrão em análises de oxigênio é um método que exige acurácia do analista, além de utilizar grandes volumes de amostra e reagentes concentrados. Desta forma, o desenvolvimento de alternativas mais robustas, e que possibilitem análises rápidas e de uso in loco vem sendo estudas. Portanto, uma das propostas deste trabalho foi a otimização das condições de análise segundo a melhor resposta do complexo e sua relação de linearidade com a concentração de oxigênio de forma a cumprir tais requisitos. Para a obtenção das respostas analíticas, foram utilizadas técnicas de espectrofotometria molecular no visível e imagens digitais, obtendo respostas promissoras em relação as figuras de mérito com coeficiente de determinação de 0,9912. Quanto a amostras de água de torneira testadas, as respostas foram comparáveis as do métodos iodométrico, sugerindo sua aplicabilidade em análises de oxigênio dissolvido. Palavras-chave: Oxigênio dissolvido. Complexo MnIII-EDTA. Imagem digital.
dc.descriptionThe objective of this work was to develop a method for analysis of oxygen dissolved in water from the formation of the MnIII-EDTA complex through the oxidation of Mn (II) by oxygen present in solution. Dissolved oxygen is considered one of the most relevant constituents of water resources, as it is directly related to the range of organisms capable of surviving (aerobic and anaerobic). The main ways to measure the concentration of oxygen in solution are the amperometric methods, use of fluorescence-based optical sensors and the iodometric. Although there are different devices for each of these techniques, their use depends on the characteristics of the environment in which they will be used. In these methods, the conditions must be optimized, and the calibration performed, except for the iodometric. Despite being considered a standard in oxygen analysis, this method requires accuracy from the analyst, in addition to using large sample volumes and concentrated reagents. Thus, the development of more robust alternatives, which enable rapid analysis and use in loco has been studied. Therefore, one of the proposals of this work was the optimization of the analysis conditions according to the best response of the complex and its relationship of linearity with the oxygen concentration to fulfill such requirements. To obtain the analytical responses, techniques of molecular spectrophotometry in the visible and digital images were used, obtaining promising answers in relation to the figures of merit with a coefficient of determination of 0.9912. As for tested tap water samples, the responses were comparable to those of iodometric methods, suggesting their applicability in dissolved oxygen analysis., the responses were comparable to those of the iodometric methods, suggesting their applicability in dissolved oxygen analyses. Keywords: Dissolved oxygen. Mn III -EDTA complex. Digital image.
dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior
dc.formatapplication/pdf
dc.languagepor
dc.publisherUniversidade Federal de Viçosa
dc.publisherAgroquímica
dc.rightsAcesso Aberto
dc.subjectÁgua - Oxigênio dissolvido
dc.subjectÁgua - Análise
dc.subjectEspectrofotometria
dc.subjectImagens digitais
dc.subjectQuímica Analítica
dc.titleMétodo para determinação de oxigênio dissolvido em águas utilizando complexo Mn III-EDTA
dc.titleMethod for determining dissolved oxygen in water using the MnIII-EDTA complex