Coeficiente de operación de un sistema formado por un refrigerador doméstico acoplado a un acumulador de agua caliente para la recuperación de energía
Registro en:
Informacion Tecnologica, v. 23, n. 2, p. 141-150, 2012.
0716-8756
0718-0764
10.4067/S0718-07642012000200016
S0718-07642012000200016
2-s2.0-84863466578.pdf
2-s2.0-84863466578
Autor
Souza, Luís M.P.
Scalon, Vicente L.
Padilha, Alcides
Resumen
An experimental apparatus containing a domestic refrigerator coupled to a vertical hot water storage tank was used for energy recovery. The original condenser of the refrigerator was maintained, but modified with a concentric tubes heat exchanger with countercurrent water and refrigerating gas flows. The coefficient of performance for the heat pump is calculated by the ratio of energy in the heat storage and the electric power consumed by the domestic refrigerator compressor. The results show that the increasing of hydrostatic pressure in the storage tank increases the water flow rate and the coefficient of performance. The proposed device also reduces the heat dissipation to the surroundings. This is more important in small confinements found in low-cost houses.