dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorLeite, Fábio Correa
dc.creatorGrimoni, Jose Aquiles B.
dc.creatorMalheiro, Fábio Mendes
dc.creatorTomiyoshi, Luiz Kazunori
dc.date2014-05-27T11:26:14Z
dc.date2016-10-25T18:35:50Z
dc.date2014-05-27T11:26:14Z
dc.date2016-10-25T18:35:50Z
dc.date2011-12-01
dc.date.accessioned2017-04-06T01:54:33Z
dc.date.available2017-04-06T01:54:33Z
dc.identifierConference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011.
dc.identifierhttp://hdl.handle.net/11449/72845
dc.identifierhttp://acervodigital.unesp.br/handle/11449/72845
dc.identifier10.1109/ESW.2011.6164724
dc.identifier2-s2.0-84859042267
dc.identifierhttp://dx.doi.org/10.1109/ESW.2011.6164724
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/893680
dc.descriptionThe traditional operational and hazard control paradigm of an electrical installation has several issues pertaining to the diversity of equipment. A large maintenance inventory is a reason for concern for any manager, but the arc flash hazard is a particularly new phenomenon and the effects of equipment diversity on this phenomenon are even newer. The class of arc hazard can be increased, simply by changing the fuse link or circuit breaker manufacturer. Management pressure to operate as well as non-standard practices and installations are also partly responsible. The aim of this study is to take a typical situation in an industrial plant and to statistically simulate, by means of a dedicated software program, the fuse arc flash interruption performance of various manufacturers. The purpose of this study is to obtain a more objective indication of the influence of different fuse link manufacturers on arc flash incident energy. © 2011 IEEE.
dc.languageeng
dc.relationConference Record of the 2011 IEEE IAS Electrical Safety Workshop, ESW 2011
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.subjectArc flash
dc.subjectFuse links
dc.subjectHazard control
dc.subjectArc Flash
dc.subjectArc flash energies
dc.subjectArc flash hazards
dc.subjectArc hazards
dc.subjectElectrical installations
dc.subjectFuse arc
dc.subjectFuse-link
dc.subjectIncident energy
dc.subjectInterruption performance
dc.subjectSoftware program
dc.subjectHazards
dc.subjectIndustrial plants
dc.subjectManagers
dc.subjectManufacture
dc.subjectArc lamps
dc.titleThe impact of fuse link manufacturers on arc flash energy
dc.typeOtro


Este ítem pertenece a la siguiente institución