Otro
Effect of light energy density on conversion degree and hardness of dual-cured resin cement
Registro en:
Operative Dentistry, v. 35, n. 1, p. 120-124, 2010.
0361-7734
10.2341/09-126-L
2-s2.0-76649118412
Autor
Komori, P. C P
Paula, A. B.
Martin, A. A.
Tango, R. N.
Sinhoreti, M. A C
Correr-Sobrinho, L.
Resumen
This study evaluated the effect of different light energy densities on conversion degree (CD) and Knoop hardness number (KHN) of RelyX ARC (RLX) resin cement. After manipulation according to the manufacturer's instructions, RLX was inserted into a rubber mold (0.8 mm X 5 mm) and covered with a Mylar strip. The tip of the lightcuring unit (LCU) was positioned in contact with the Mylar surface. Quartz-tungsten-halogen (QTH) and light-emitting diode (LED) LCUs with light densities of 10, 20 and 30 J/cm2 were used to light-cure the specimens. After light curing, the specimens were stored dry in lightproof containers at 37°C. After 24 hours, the CD was analyzed by FT-Raman and, after an additional 24-hours, samples were submitted to Knoop hardness testing. The data of the CD (%) and KHN were submitted to two-way ANOVA and the Tukey's test (α=0.05). QTH and LED were effective light curing units. For QTH, there were no differences among the light energy densities for CD or KHN. For LED, there was a significant reduction in CD with the light energy density set at 10 J/cm2. KHN was not influenced by the lightcuring unit and by its light energy density. © Operative Dentistry.
Materias
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Evaluation of marginal microleakage in Class II cavities: Effect of microhybrid, flowable, and compactable resins
Peris, Alessandra Rezende; Duarte Jr., Sillas; Andrade, Marcelo Ferrarezi de -
Evaluation of marginal microleakage in Class II cavities: Effect of microhybrid, flowable, and compactable resins
Universidade Estadual de Campinas (UNICAMP); Univ. of MN School of Dentistry; Universidade Estadual Paulista (Unesp) (2003-02-01)Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). ... -
Evaluation of marginal microleakage in Class II cavities: Effect of microhybrid, flowable, and compactable resins
Universidade Estadual de Campinas (UNICAMP); Univ. of MN School of Dentistry; Universidade Estadual Paulista (Unesp) (2003-02-01)Objective: The goal of the present study was to evaluate the microleakage on the cementum/dentin and enamel surfaces in Class II restorations, using different kinds of resin composite (microhybrid, flowable, and compactable). ...