Otro
The influence of zero-value subtraction on the performance of two laser fluorescence devices for detecting occlusal caries in vitro
Registro en:
Journal of the American Dental Association, v. 139, n. 8, p. 1105-1112, 2008.
0002-8177
10.14219/jada.archive.2008.0313
2-s2.0-52449104337
Autor
Rodrigues, Jonas de A.
Hug, Isabel
Diniz, Michele B.
Cordeiro, Rita C. L.
Lussi, Adrian
Resumen
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to detect occlusal caries. Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site. Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy for the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly. Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure. Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Materias
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
Fluorescence excitation-emission matrix spectroscopy as a tool for determining quality of sparkling wines
Elcoroaristizabal S.; Callejón R.M.; Amigo J.M.; Ocaña-González J.A.; Morales M.L.; Ubeda C. (Elsevier Ltd, 2016) -
Solubilization of phenols by multimolecular aggregates formed by low molecular weight hyperbranched polyglycidol
Olea A.F.; Acevedo B.; Ossandon L.; Worrall D. (Elsevier B.V., 2017) -
Enhanced molecular visualization of root colonization and growth promotion by Bacillus subtilis EA-CB0575 in different growth systems
Posada, L.F.; Álvarez, J.C.; Romero-Tabarez, M.; de-Bashan, L.; Villegas-Escobar, V. (Elsevier GmbH, 2018-01-01)Bacillus subtilis EA-CB0575 is a plant growth-promoting bacterium (PGPB) associated with banana and tomato crops. Root colonization is an important trait for PGPB microorganisms and potentiates the bacterial effect related ...