Trabalho apresentado em evento
Flashover phenomenon: an analysis with influence of the thickness of the layer pollution of the high voltage polluted insulators
Registro en:
Conference Record of IEEE International Symposium on Electrical Insulation, p. 546-549.
0164-2006
10.1109/ELINSL.1994.401397
WOS:A1994BA96P00132
2-s2.0-0028564615
Autor
Astorga, Oscar Armando Maldonado [UNESP]
do Prado, Afonso Jose [UNESP]
Resumen
Results of the analysis of dynamic behavior of flashover phenomenon on the high voltage-polluted insulators are presented. These results were taken from a mathematical and an experimental model that introduce the variable thickness influence of the layer pollution deposited on the high-voltage insulator surface. Analysis of the flashover was done by way of introducing a variation in the thickness of the channel of Obenaus' model, simulating a layer pollution of variable thickness. The objective was to obtain a better reproduction of the real layer pollution deposited on the insulator that works in the polluted regions. Two types of thickness variations were used: a sudden variation, using a step; and a soft variation, using a ramp; that were put along the way of the discharge. Comparison between the mathematical and experimental models showed that introduction of a ramp makes Obenaus' model more efficient in analyzing behavior of flashover phenomenon. UNESP,FEIS,DEPT ENGN ELETR,BR-15378000 ILHA SOLTEIRA,SP,BRAZIL UNESP,FEIS,DEPT ENGN ELETR,BR-15378000 ILHA SOLTEIRA,SP,BRAZIL