dc.contributorUniversidade Estadual Paulista (Unesp)
dc.creatorAlvarenga, Fábio Augusto de Santi [UNESP]
dc.creatorPinelli, Camila [UNESP]
dc.creatorLoffredo, Leonor de Castro Monteiro [UNESP]
dc.date2015-08-06T16:13:56Z
dc.date2015-08-06T16:13:56Z
dc.date2015
dc.date.accessioned2023-09-12T05:52:34Z
dc.date.available2023-09-12T05:52:34Z
dc.identifierhttp://www.eurjdent.com/article.asp?issn=1305-7456;year=2015;volume=9;issue=1;spage=1;epage=5;aulast=de
dc.identifierEuropean Journal of Dentistry, v. 9, n. 1, p. 1-5, 2015.
dc.identifier1305-7456
dc.identifierhttp://hdl.handle.net/11449/126095
dc.identifier10.4103/1305-7456.149628
dc.identifier5663622442588861
dc.identifier4021286315086194
dc.identifier3469868853605212
dc.identifier5663622442588861
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8775484
dc.descriptionThe aim of this study was to investigate the reliability of visual and digital methods to assess marginal microleakage in vitro. Materials and Methods: Typical Class V preparations were made in bovine teeth and filled with composite resin. After dye penetration (0.5% basic fuchsin), teeth were sectioned and the 53 obtained fragments were assessed according to visual (stereomicroscope) and digital methods (Image Tool Software ® -ITS) (University of Texas Health Science Center-San Antonio Dental School, USA). Two calibrated examiners (A and B) evaluated dye penetration, by means of a stereomicroscope with ×20 magnification (scores), and by the ITS (millimeters). The intra- and inter-examiner agreement was estimated according to Kappa statistics (κ), and intraclass correlation coefficient (ρ). Results: In relation to the visual method, the intra-examiner agreement was almost perfect (κA = 0.87) and substantial (κB = 0.76), respectively to the examiner A and B. The inter-examiner agreement showed an almost perfect reliability (κ = 0.84). For the digital method, the intra-examiner agreement was almost perfect for both examiners and equal to ρ = 0.99, and so was the inter-examiner agreement value. Conclusion: Visual (stereomicroscope) and digital methods (ITS) showed high levels of intra- and inter-examiner reproducibility when marginal microleakage was assessed.
dc.descriptionUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, n. 1680, Centro, CEP 14801-903, SP, Brasil
dc.descriptionUniversidade Estadual Paulista Júlio de Mesquita Filho, Faculdade de Odontologia de Araraquara, Araraquara, Rua Humaitá, n. 1680, Centro, CEP 14801-903, SP, Brasil
dc.descriptionDepartment of Community Dentistry
dc.descriptionDepartment of Restorative Dentistry
dc.format1-5
dc.languageeng
dc.relationEuropean Journal of Dentistry
dc.relation0,749
dc.rightsAcesso restrito
dc.sourceCurrículo Lattes
dc.subjectAssessment
dc.subjectComposite resin
dc.subjectMicroleakage
dc.subjectReproducibility of results
dc.titleReliability of marginal microleakage assessment by visual and digital methods
dc.typeArtigo


Este ítem pertenece a la siguiente institución