dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorLobo, F. A.
dc.creatorVillafranca, A. C.
dc.creatorOliveira, A. P. de
dc.creatorMoraes, M. de
dc.date2014-05-20T15:10:30Z
dc.date2016-10-25T17:44:55Z
dc.date2014-05-20T15:10:30Z
dc.date2016-10-25T17:44:55Z
dc.date2005-01-01
dc.date.accessioned2017-04-05T22:49:27Z
dc.date.available2017-04-05T22:49:27Z
dc.identifierEclética Química. Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP, v. 30, n. 2, p. 61-68, 2005.
dc.identifier0100-4670
dc.identifierhttp://hdl.handle.net/11449/27666
dc.identifierhttp://acervodigital.unesp.br/handle/11449/27666
dc.identifier10.1590/S0100-46702005000200008
dc.identifierS0100-46702005000200008
dc.identifierS0100-46702005000200008.pdf
dc.identifierhttp://dx.doi.org/10.1590/S0100-46702005000200008
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/872358
dc.descriptionEste trabalho propõe o desenvolvimento de um procedimento analítico para a determinação em linha de estanho em soluções analíticas empregando a técnica de espectrometria de absorção atômica com nebulização térmica em tubo metálico aquecido na chama (TS-FF-AAS) como alternativa ao uso da chama de óxido nitroso-acetileno em espectrometria de absorção atômica, cujo comburente apresenta um custo elevado frente ao ar comprimido. Foram avaliados parâmetros para a otimização do sistema, tais como: vazão do carregador (ar), volume de amostra injetada e concentração do ácido (HCl). Foi construída curva analítica linear [A= -0,00163 + 0,00319 [Sn], (r= 0,9998)] no intervalo de 10 a 80 mg Sn L-1. O limite de detecção, o desvio padrão relativo (n=12) e a freqüência analítica foram: 1,7 mg L-1 Sn, £ 2,7% and 120 h-1 respectivamente. O sistema TS-FF-AAS é uma alternativa para a determinação de Sn.
dc.descriptionThis work propose the development of analytical procedure for on line tin determination in analytical solutions by thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) as alternative to nitrous oxide-acetylene flame by atomic absorption spectrometry, whose oxidant presents high costs with respect to air. Parameters were evaluated for the optimization of the system: flow of the carrier (air), volume of injected sample and concentration of the acid (HCl). The linear analytical curve [A= -0,00163 +0,00319 Sn], (r = 0,9998) ] was constructed on interval of 10 the 80 mg L-1 Sn. The detection limit, the relative standard deviations (n=12) and analytical frequency were: 1,7 mg L-1 Sn, £ 2,7% and 120 h-1, respectively. The TS-FF-AAS is an alternative for the determination of Sn.
dc.descriptionFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.descriptionConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.languagepor
dc.publisherEditora Unesp
dc.relationEclética Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectTS-FF-AAS
dc.subjectestanho
dc.subjecttubo metálico
dc.subjectTS-FF-AAS
dc.subjecttin
dc.subjectmetallic tube
dc.titleSistema TS-FF-AAS com chama acetileno-ar como alternativa em relação à chama acetileno-óxido nitroso em FAAS na determinação de estanho
dc.typeOtro


Este ítem pertenece a la siguiente institución