dc.contributorGrupo de Investigación Ecitrónica
dc.creatorAperador Chaparro, William Arnulfo
dc.creatorVera López, Enrique
dc.creatorMora Parada, José Manuel
dc.date.accessioned2023-06-05T19:43:05Z
dc.date.accessioned2023-09-06T21:17:46Z
dc.date.available2023-06-05T19:43:05Z
dc.date.available2023-09-06T21:17:46Z
dc.date.created2023-06-05T19:43:05Z
dc.date.issued2007
dc.identifier0120-2650
dc.identifierhttps://repositorio.escuelaing.edu.co/handle/001/2384
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/8707386
dc.description.abstractEn este trabajo se presenta la descripción matemática de la nueva técnica electroquímica no lineal utilizada para la evaluación de la corrosión llamada Distorsión de Intermodulación (IMD) también conocida como Modulación de Frecuencia Electroquímica (EFM); esta es una técnica electroquímica en la cual dos potenciales de señal sinusoidal son sumados y aplicados a una muestra que se evaluó frente a la corrosión por un potenciostato. La corriente resultante es medida y los datos de dominio de tiempo son convertidos al dominio de frecuencia para medir la señal a las frecuencias fundamentales aplicadas, a los armónicos de las frecuencias fundamentales y a las frecuencias de intermodulación. Con la técnica EFM la velocidad de corrosión puede obtenerse instantáneamente, sin el conocimiento previo de los parámetros Tafel. Una ventaja especial de la técnica EFM es su capacidad de mando de validación de datos inherentes usando “factores de causalidad”. Con esto se muestra que la técnica EFM puede usarse con éxito en varios sistemas en los que se genere degradación del material.
dc.description.abstractIn this work, the mathematical description of the new non lineal electrochemical technique is presented, which is used for evaluating the corrosion called intermodulation distortion (IMD), also well-know as electrochemical frequency modulation (EFM). It is an electrochemical technique where two potentials of sinusoidal signal are added up and applied to one sample that will be evaluated in face to corrosion by a potenciostate. The resulting current is measure and the data of time domain are turned to frequency domain for measuring the signal to applied fundamental frequencies, to harmonics of fundamental frequencies and the intermodulation frequencies. With the EFM technique, the rate corrosion can be obtained instantaneously without the previous knowledge of tafel parameters. A special advantage of EFM technique is his capacity of validation control of inherent data using “causality factors”. With this, it is shown the EFM technique can be used with success in several systems in those where material degradation is generated.
dc.languagespa
dc.publisherUniversidad de Antioquia
dc.publisherColombia
dc.relation146
dc.relation1
dc.relation143
dc.relation39
dc.relationN/A
dc.relationRevista Colombiana de Física
dc.relationR W Bosch; J Hubrecht; W F Bogaerts; B C Syrett, Electrochemical frequency modulation: A New Electrochemical Technique for Online Corrosion Monitoring. Corrosion; 57 (2001) 60.
dc.relationDavid A Eden, Practical Measurements Using Non-Linear Analysis Techniques – Harmonic Distortion and Intermodulation Distortion; InterCorr International, Inc.14503 Bammel North Houston, Suite 300, Houston, Texas 77014
dc.relationEsra Kus_, Florian Mansfeld, Corrosion Science 48 (2006) 965–979
dc.rightsinfo:eu-repo/semantics/closedAccess
dc.titleDescripción de la modulación de frecuencia electroquímica utilizada para las medidas de velocidad de corrosión
dc.typeArtículo de revista


Este ítem pertenece a la siguiente institución