dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorGirotto, G.
dc.creatorNogueira, K. L.
dc.creatorMoura, J. A.
dc.creatorSouza, J. B.
dc.creatorGiacometti, L. L.
dc.creatorMarchi, M. R.R.
dc.creatorTognolli, J. O.
dc.date2014-05-20T14:18:53Z
dc.date2016-10-25T17:40:47Z
dc.date2014-05-20T14:18:53Z
dc.date2016-10-25T17:40:47Z
dc.date2007-01-01
dc.date.accessioned2017-04-05T22:29:40Z
dc.date.available2017-04-05T22:29:40Z
dc.identifierEclética Química. Fundação Editora da Universidade Estadual Paulista Júlio de Mesquita Filho - UNESP, v. 32, n. 2, p. 61-67, 2007.
dc.identifier0100-4670
dc.identifierhttp://hdl.handle.net/11449/25692
dc.identifierhttp://acervodigital.unesp.br/handle/11449/25692
dc.identifier10.1590/S0100-46702007000200010
dc.identifierS0100-46702007000200010
dc.identifierS0100-46702007000200010.pdf
dc.identifierhttp://dx.doi.org/10.1590/S0100-46702007000200010
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/870549
dc.descriptionMuitos métodos analíticos estão sendo desenvolvidos visando à determinação de contaminantes orgânicos, especialmente alteradores endócrinos. Tais métodos baseiam-se geralmente na extração em fase sólida (SPE) seguida por determinação cromatográfica (CG ou HPLC). No presente trabalho utilizou-se ferramentas quimiométricas no processo de SPE para avaliar os principais fatores que influenciam tal processo e as interações entre os mesmos. Foram analisadas matrizes de água subterrânea fortificada com hormônios (17 b estradiol, estrona e 17 b etinilestradiol) e a determinação analítica foi feita por HPLC/Fluorescência. Um planejamento fatorial completo foi utilizado. Os fatores escolhidos incluíram: condicionamento da fase sólida, concentração dos analitos, volume da amostra e solvente de eluição. As melhores condições obtidas foram: 500 mL da amostra, condicionamento da fase sólida (C18) com acetona (4mL), metanol (6 mL) e água pH 3(10 mL), e eluição dos analitos com 4 mL de acetona.
dc.descriptionSeveral analytical methods have been proposed for organic pollutants determination in water, specially endocrine disrupters. These methods are frequently based in solid phase extraction (SPE) followed by chromatographic determination (GC or HPLC). In this work it was used chemometric tools on experimental design and experimental data treatment to evaluate the principal factors in SPE process and their interactions. It was used water matrices fortified with hormones (17 b estradiol, estrone and 17 b ethinylestradiol) and HPLC/Fluorescence did analytical determination. It was used a factorial complete design. The choosed factors included: solid phase type, analytes concentration, sample volumen, eluent composition, analytes concentration and solvents to solid phase conditioning. The best condition obtained in this initial procedure included: 500 mL sample, conditioning SPE cartridge with acetone (4mL), methanol (6 mL) and water pH 3(10 mL), and analytes elution with acetone.
dc.languagepor
dc.publisherEditora Unesp
dc.relationEclética Química
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectalteradores endócrinos
dc.subjectplanejamento fatorial
dc.subjectextração em fase sólida
dc.subjectchemometry
dc.subjectestrogens
dc.subjectSPE
dc.titleEstrógenos em água: otimização da extração em fase sólida utilizando ferramentas quimiométricas
dc.typeOtro


Este ítem pertenece a la siguiente institución