dc.contributorUniversidade Estadual Paulista (UNESP)
dc.creatorSilva, Robson Willians da Costa
dc.creatorMalagutti Filho, Walter
dc.date2013-09-30T20:04:42Z
dc.date2014-05-20T14:16:51Z
dc.date2016-10-25T17:39:41Z
dc.date2013-09-30T20:04:42Z
dc.date2014-05-20T14:16:51Z
dc.date2016-10-25T17:39:41Z
dc.date2009-09-01
dc.date.accessioned2017-04-05T22:23:03Z
dc.date.available2017-04-05T22:23:03Z
dc.identifierEngenharia Sanitaria e Ambiental . ABES , v. 14, n. 3, p. 327-336, 2009.
dc.identifier1413-4152
dc.identifierhttp://hdl.handle.net/11449/25062
dc.identifierhttp://acervodigital.unesp.br/handle/11449/25062
dc.identifier10.1590/S1413-41522009000300006
dc.identifierS1413-41522009000300006
dc.identifierWOS:000271424600006
dc.identifierS1413-41522009000300006.pdf
dc.identifierhttp://dx.doi.org/10.1590/S1413-41522009000300006
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/869995
dc.descriptionDentro do gerenciamento de áreas contaminadas, a aplicação de métodos geofísicos, em estudos de área contaminada, constitui uma metodologia confirmatória. Este procedimento - mais precisamente o método da eletrorresistividade por meio das técnicas da sondagem elétrica vertical e imageamento elétrico - foi aplicado no cemitério de Vila Rezende, em Piracicaba, São Paulo, para investigar e mapear a contaminação do cemitério por necrochorume. Os resultados indicam uma profundidade do nível freático entre 3,1 e 5,1 m, com duas direções de fluxo subterrâneo, uma a SW e outra a SE. Tanto as prováveis plumas de contaminação, que têm as mesmas direções de fluxo subterrâneo, quanto as anomalias condutivas verificadas nas seções geoelétricas confirmam as suspeitas de contaminação na área.
dc.descriptionInside of the administration of contaminated areas, the application of geophysical methods, in studies of contaminated area, constitutes a confirmatory methodology. This procedure - more precisely the electrical resistivity method through the techniques of the vertical electric sounding and electrical imaging techniques, was applied at Vila Rezendeâ TMs cemetery, Piracicaba, São Paulo, Brazil, to investigate and to map the contamination of the cemetery for necrochorume. The results indicate a depth of water table among 3.1 and 5.1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plumes, that have the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area.
dc.descriptionCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.languagepor
dc.publisherABES
dc.relationEngenharia Sanitária e Ambiental
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjecteletrorresistividade
dc.subjectcontaminação
dc.subjectnecrochorume
dc.subjectinvestigação
dc.subjecteletrorresistivity
dc.subjectcontamination
dc.subjectnecrochorume
dc.subjectinvestigation
dc.titleO emprego de métodos geofísicos na fase de investigação confirmatória em cemitérios contaminados
dc.typeOtro


Este ítem pertenece a la siguiente institución