es | en | pt | fr
    • Presentación
    • Países
    • Instituciones
    • Participa
        JavaScript is disabled for your browser. Some features of this site may not work without it.
        Ver ítem 
        •   Inicio
        • Colombia
        • Universidades
        • Universidad Tecnológica de Bolivar UTB (Colombia)
        • Ver ítem
        •   Inicio
        • Colombia
        • Universidades
        • Universidad Tecnológica de Bolivar UTB (Colombia)
        • Ver ítem

        A mixed-integer convex approximation for optimal load redistribution in bipolar DC networks with multiple constant power terminals

        Fecha
        2022
        Registro en:
        Montoya, O. D., Molina-Cabrera, A., & Gil-González, W. (2022). A mixed-integer convex approximation for optimal load redistribution in bipolar DC networks with multiple constant power terminals. Results in Engineering, 16(100689), 100689. https://doi.org/10.1016/j.rineng.2022.100689
        https://hdl.handle.net/20.500.12585/12102
        https://doi.org/10.1016/j.rineng.2022.100689
        Universidad Tecnológica de Bolívar
        Repositorio Universidad Tecnológica de Bolívar
        https://repositorioslatinoamericanos.uchile.cl/handle/2250/8683013
        Autor
        Montoya, Oscar Danilo
        Molina-Cabrera, Alexander
        Gil-González, Walter
        Institución
        • Universidad Tecnológica de Bolivar UTB (Colombia)
        Resumen
        This paper proposes a mixed-integer convex model for optimal load-balancing in bipolar DC networks while considering multiple constant power terminals. The proposed convex model combines the Branch and Cut method with interior point optimization to solve the problem of optimal load balancing in bipolar DC networks. Additionally, the proposed convex model guarantees that global optimum of the problem is found, which ensures minimal power losses in the bipolar DC distribution grid branches, as the total monopolar load consumption has been balanced at the substation's terminals. In addition, an optimal load balancing improves the voltage profiles due to current redistribution between the positive and negative poles. Numerical results in the 21- and 85-bus test feeders and a comparison with three metaheuristic techniques show the effectiveness of the proposed convex model in reducing the total grid imbalance while minimizing the power losses and improving the voltage profiles.
        Materias

        Mostrar el registro completo del ítem


        Red de Repositorios Latinoamericanos
        + de 8.000.000 publicaciones disponibles
        500 instituciones participantes
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Ingreso Administradores
        Colecciones destacadas
        • Tesis latinoamericanas
        • Tesis argentinas
        • Tesis chilenas
        • Tesis peruanas
        Nuevas incorporaciones
        • Argentina
        • Brasil
        • Colombia
        • México
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Red de Repositorios Latinoamericanos | 2006-2018
         

        EXPLORAR POR

        Instituciones
        Fecha2011 - 20202001 - 20101951 - 20001901 - 19501800 - 1900

        Explorar en Red de Repositorios

        Países >
        Tipo de documento >
        Fecha de publicación >
        Instituciones >

        Red de Repositorios Latinoamericanos
        + de 8.000.000 publicaciones disponibles
        500 instituciones participantes
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Ingreso Administradores
        Colecciones destacadas
        • Tesis latinoamericanas
        • Tesis argentinas
        • Tesis chilenas
        • Tesis peruanas
        Nuevas incorporaciones
        • Argentina
        • Brasil
        • Colombia
        • México
        Dirección de Servicios de Información y Bibliotecas (SISIB)
        Universidad de Chile
        Red de Repositorios Latinoamericanos | 2006-2018