Otro
Effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures-2D FEA
Registro en:
Computer Methods and Programs In Biomedicine. Clare: Elsevier B.V., v. 92, n. 2, p. 213-223, 2008.
0169-2607
10.1016/j.cmpb.2008.07.009
WOS:000260919300007
Autor
Ricardo Barao, Valentim Adelino
Assunção, Wirley Goncalves
Tabata, Lucas Fernando
Sousa, Edson Antonio Capello
Rocha, Eduardo Passos
Resumen
The study aimed to evaluate the effect of different mucosa thickness and resiliency on stress distribution of implant-retained overdentures using a two-dimensional finite element analysis. Models were used in order to simulate two situations. In group A, model represented an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system while in group B, model simulated an edentulous mandible supporting an overdenture retained by two-splinted-implants connected with bar-clip system associated with two-distally placed o'ring system. In each group, mucosa assumed three characteristics of thickness (1, 3 and 5 mm) in the resiliencies: hard, resilient and soft, respectively Evaluation was performed on Ansys software. Group A showed higher stress values regardless of the mucosa characteristics. Overall, stress decreased at the supporting tissues as mucosa. thickness and resiliency increased. Regarding supporting tissues, cortical bone showed the highest stress values. The use of bar-clip attachment system with distally placed o'ring attachment design optimized the stress distribution. (C) 2008 Elsevier B.V. All rights reserved. Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)