dc.descriptionEl Laboratorio de Servicios de Análisis e Investigación en Alimentos (LSAIA) del 1NIAP en la Estación Experimental Santa Catalina y se basó en los siguientes parámetros: selectividad, linealidad y rango lineal, precisión, exactitud, límite de detección y cuantificación e incertidumbre. La evaluación de los parámetros demostró lo siguiente: el método analítico es selectivo porque no se evidencia que otras sustancias interfieran en el análisis de la OTA y además se obtuvo un porcentaje de pureza de pico del 100%. Se probó que el método es lineal en un rango de 1,80 a 15,0 Mg/kg; es preciso ya que para la repetibilidad se obtuvo una RSDr < 20% y para la reproducibilidad una RSDR < 30%; y finalmente es exacto porque se obtuvo un porcentaje de recuperación de 89,64. Además los límites de detección y cuantificación fueron 0,54 Mg/kg y 1,80 Mg/kg respectivamente y el resultado final está asociado con una incertidumbre de 0,60. Éste método fue aplicado satisfactoriamente en la determinación de OTA en 45 muestras de café tostado de cinco marcas diferentes tomadas en Quito en Septiembre, Octubre y Noviembre del 2010. Se obtuvo un 0% de OTA.
dc.descriptionThe validation of a quantitative analysis method to determine Ochratoxin A (OTA) in roasted coffee by High Performance Liquid Chromatography (HPLC), using inmunoaffinity columns and a fluorescence detector is described. This validation was performed at the Analytical Services and Food Research Laboratory (LSAIA) of INIAP at Santa Catalina Station and it was based on the following parameters: selectivity, linearity and lineal range, precision, accuracy, detection and quantification limits and uncertainty. The evaluation of these parameters showed the following: the analytic method is selective because there is no evidence of interference with other substances in OTA analysis and because a 100% of peak purity was obtained. It was proved that the method is linear in the range of 1,80 to 15,0 Mg/kg; it is precise because RSDr < 20% was obtained for repeatability and a RSDr < 30% was obtained for reproducibility; finally the method is exact because the recovery was 89,64%. Detection and quantification limits were 0,54 Mg/kg and 1,80 Mg/kg respectively, and the final result is associated with an uncertainty of 0,60. This method was applied successfully in OTA determination of 45 samples of roasted coffee of five different brands taken in Quito in September, October and November of 2010. 0% of OTA was obtained.
dc.format3 p.
dc.formatapplication/pdf
dc.languageesp
dc.publisherQuito: Universidad Central del Ecuador, Facultad de Ciencias Químicas, Escuela de Bioquímica y Farmacia, Carrera de Química de Alimentos, 2011. 130 p.
dc.subjectCAFÉ TOSTADO
dc.subjectOCRATOXINAS
dc.subjectOCRATOXINA A
dc.subjectMICOTOXINAS
dc.subjectHPLC
dc.subjectCROMATOGRAFÍA LIQUIDA DE ALTA RESOLUCIÓN
dc.subjectVALIDACIÓN
dc.subjectTESIS
dc.titleValidación del método y evaluación del contenido de ocratoxina A en café tostado de consumo local por el método de cromatografía liquida de alta resolución