Determinação da tireoglobulina no lavado da agulha da punção aspirativa de linfonodos cervicais para detecção de metástases do câncer papilar de tireoide

dc.creatorZanella, André Borsatto
dc.creatorMeyer, Erika Laurini de Souza
dc.creatorBalzan, Leticia Maffazzioli Santos
dc.creatorSilva, Antonio Carlos da
dc.creatorCamargo, Joiza Lins
dc.creatorMigliavaca, Alceu
dc.creatorGuimaraes, Jose Ricardo
dc.creatorMaia, Ana Luiza Silva
dc.date2012-05-03T01:26:40Z
dc.date2010
dc.identifier0004-2730
dc.identifierhttp://hdl.handle.net/10183/40093
dc.identifier000763977
dc.descriptionObjetivo: O objetivo deste estudo foi avaliar a acurácia da dosagem de tireoglobulina no lavado da agulha da punção aspirativa (PAAF-Tg) de linfonodos (LN) cervicais para detecção de metástases do câncer papilar de tireoide (CPT). Sujeitos e métodos: Foram incluídos 43 pacientes (51,4 ± 14,6 anos) com diagnóstico de CPT e evidência de LN cervicais aumentados. Os LN suspeitos foram submetidos à punção aspiração com agulha fina guiada por ecografia para análise citológica e dosagem de tireoglobulina (PAAF-Tg). Resultados: A mediana dos valores de PAAF-Tg nos LN metastáticos (n = 5) foi 3.419,0 ng/mL (11,1-25.538), enquanto nos LN não metastáticos (n= 38) a mediana foi de 3,7 ng/mL (0,8-7,4). Utilizando-se o nível de 10 ng/mL como ponto de corte, observaram-se sensibilidade e especificidade de 100%. Os níveis de TSH sérico não interferiram na dosagem de PAAF-Tg (3,3 e 3,8 ng/mL nos grupos com TSH supresso (TSH 0,07 mUI/mL) e hipotireoidismo (TSH 97,4 mUI/mL), respectivamente, P = 0,2). Conclusão: Os resultados demonstram que a dosagem de PAAF-Tg é uma ferramenta importante no diagnóstico de metástases do CPT, podendo ser utilizada independente do “status” tireoidiano.
dc.descriptionObjective: The aim of this study was to evaluate the accuracy of the measurement of thyroglobulin in washout needle aspiration biopsy (FNAB-Tg) to detect papillary thyroid cancer (PTC) metastases. Subjects and methods: Forty-three patients (51.4 ± 14.6 years) with PTC diagnosis and evidence of enlarged cervical lymph nodes (LN) were included. An ultrasound-guided fine-needle aspiration of suspicious LN was performed, for both cytological examination and measurement of FNAB-Tg. Results: The median values of FNAB-Tg in patients with metastatic LN (n = 5) was 3,419 ng/mL (11.1-25,538), while patients without LN metastasis (n = 38) showed levels of 3.7 ng/mL (0.8-7.4). Considering a 10 ng/mL cutoff value for FNAB-Tg, the sensitivity and specificity was 100%. There were no differences on the median of FNAB-Tg measurements between those on (TSH 0.07 mUI/mL) or off levothyroxine (TSH 97.4 mUI/mL) therapy (3.3 vs. 3.8 ng/mL, respectively; P = 0.2). Conclusion: The results show that evaluation of FNAB-Tg in cervical LN is a valuable diagnostic tool for PTC metastases that can be used independent of the thyroid status.
dc.formatapplication/pdf
dc.languagepor
dc.relationArquivos brasileiros de endocrinologia & metabologia. Vol. 54, n. 6 (ago. 2010), p. 550-554
dc.rightsOpen Access
dc.subjectMetástase neoplásica
dc.subjectNeoplasias da glândula tireóide
dc.subjectBiópsia por agulha
dc.subjectLinfonodos
dc.subjectTireoglobulina
dc.subjectPapillary thyroid carcinoma
dc.subjectMetastases in cervical lymph nodes
dc.subjectThyroglobulin;
dc.subjectTSH
dc.titleThyroglobulin measurements in washout of fine needle aspirates in cervical lymph nodes for detection of papillary thyroid cancer metastases
dc.titleDeterminação da tireoglobulina no lavado da agulha da punção aspirativa de linfonodos cervicais para detecção de metástases do câncer papilar de tireoide
dc.typeArtigo de periódico
dc.typeNacional


Este ítem pertenece a la siguiente institución