dc.description | Objetivo: O objetivo deste estudo foi avaliar a acurácia da dosagem de tireoglobulina no lavado da agulha da punção aspirativa (PAAF-Tg) de linfonodos (LN) cervicais para detecção de metástases do câncer papilar de tireoide (CPT). Sujeitos e métodos: Foram incluídos 43 pacientes (51,4 ± 14,6 anos) com diagnóstico de CPT e evidência de LN cervicais aumentados. Os LN suspeitos foram submetidos à punção aspiração com agulha fina guiada por ecografia para análise citológica e dosagem de tireoglobulina (PAAF-Tg). Resultados: A mediana dos valores de PAAF-Tg nos LN metastáticos (n = 5) foi 3.419,0 ng/mL (11,1-25.538), enquanto nos LN não metastáticos (n= 38) a mediana foi de 3,7 ng/mL (0,8-7,4). Utilizando-se o nível de 10 ng/mL como ponto de corte, observaram-se sensibilidade e especificidade de 100%. Os níveis de TSH sérico não interferiram na dosagem de PAAF-Tg (3,3 e 3,8 ng/mL nos grupos com TSH supresso (TSH 0,07 mUI/mL) e hipotireoidismo (TSH 97,4 mUI/mL), respectivamente, P = 0,2). Conclusão: Os resultados demonstram que a dosagem de PAAF-Tg é uma ferramenta importante no diagnóstico de metástases do CPT, podendo ser utilizada independente do “status” tireoidiano. | |
dc.description | Objective: The aim of this study was to evaluate the accuracy of the measurement of thyroglobulin in washout needle aspiration biopsy (FNAB-Tg) to detect papillary thyroid cancer (PTC) metastases. Subjects and methods: Forty-three patients (51.4 ± 14.6 years) with PTC diagnosis and evidence of enlarged cervical lymph nodes (LN) were included. An ultrasound-guided fine-needle aspiration of suspicious LN was performed, for both cytological examination and measurement of FNAB-Tg. Results: The median values of FNAB-Tg in patients with metastatic LN (n = 5) was 3,419 ng/mL (11.1-25,538), while patients without LN metastasis (n = 38) showed levels of 3.7 ng/mL (0.8-7.4). Considering a 10 ng/mL cutoff value for FNAB-Tg, the sensitivity and specificity was 100%. There were no differences on the median of FNAB-Tg measurements between those on (TSH 0.07 mUI/mL) or off levothyroxine (TSH 97.4 mUI/mL) therapy (3.3 vs. 3.8 ng/mL, respectively; P = 0.2). Conclusion: The results show that evaluation of FNAB-Tg in cervical LN is a valuable diagnostic tool for PTC metastases that can be used independent of the thyroid status. | |
dc.format | application/pdf | |
dc.language | por | |
dc.relation | Arquivos brasileiros de endocrinologia & metabologia. Vol. 54, n. 6 (ago. 2010), p. 550-554 | |
dc.rights | Open Access | |
dc.subject | Metástase neoplásica | |
dc.subject | Neoplasias da glândula tireóide | |
dc.subject | Biópsia por agulha | |
dc.subject | Linfonodos | |
dc.subject | Tireoglobulina | |
dc.subject | Papillary thyroid carcinoma | |
dc.subject | Metastases in cervical lymph nodes | |
dc.subject | Thyroglobulin; | |
dc.subject | TSH | |
dc.title | Thyroglobulin measurements in washout of fine needle aspirates in cervical lymph nodes for detection of papillary thyroid cancer metastases | |
dc.title | Determinação da tireoglobulina no lavado da agulha da punção aspirativa de linfonodos cervicais para detecção de metástases do câncer papilar de tireoide | |
dc.type | Artigo de periódico | |
dc.type | Nacional |