dc.creatorALARCON ANGELES, GEORGINA; 161741
dc.creatorTapia Espitia, Diana
dc.creatorGOMEZ HERNANDEZ, MARTIN; 123149
dc.creatorHurtado y de la Peña, Marcela;#0000-0003-3546-5986
dc.creatorAlarcón Ángeles, Georgina
dc.creatorTapia Espitia, Diana
dc.creatorGómez Hernández, Martín
dc.creatorHurtado y de la Peña, Marcela
dc.date.accessioned2023-04-26T17:03:35Z
dc.date.accessioned2023-07-20T16:19:09Z
dc.date.available2023-04-26T17:03:35Z
dc.date.available2023-07-20T16:19:09Z
dc.date.created2023-04-26T17:03:35Z
dc.date.issued2022
dc.identifierhttp://hdl.handle.net/11191/9634
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7718575
dc.description.abstractEn este trabajo se presenta el desarrollo de biosensores electroquímicos de ADN y se evalúa la reproducibilidad y estabilidad del ADN inmovilizado sobre el sustrato, mediante voltamperometría diferencial de pulso. Se describe el diseño, construcción de los biosensores en electrodos impresos y electrodos de grafito, empleando inmovilización por adsorción física y matriz de grafito, se reporta la evaluación diferentes técnicas de inmovilización empleadas. Los resultados muestran que los biosensores basados en matriz de grafito presentan una mejora en la señal del ADN, mientras que en electrodos impresos se observa inactivación electroquímica del ADN, por lo que se sugieren como electrodos portátiles de un sólo uso. Los resultados mostraron la mejor inmovilización del ADN es en biosensores de matriz de grafito, mostrando reproducibilidad y repetibilidad menor al 10%, la estabilidad de los biosensores muestra que la señal del ADN disminuye en un 18% respecto a la señal de inicio, en un periodo de 4 semanas.
dc.description.abstractIn this work, the development of electrochemical DNA biosensors is presented and the reproducibility and stability of DNA immobilized on the substrate is evaluated by differential pulse voltammetry. The design, construction of the biosensors in screen printed electrodes and graphite, using immobilization by physical adsorption and graphite matrix, is described, the evaluationof different immobilization techniques used is reported. The results show that biosensors based on graphite matrix present an improvement in the DNA signal, while electrochemical inactivation of DNA is observed in screen printed electrodes, which is why they are suggested as single-use portable electrodes. The results showed that the best immobilization of DNA is in graphite matrix biosensors, showing reproducibility and repeatability of less than 10%, the stability of the biosensors shows that the DNA signal decreases by 18% compared to start signal, in a period of 4 weeks.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 8, número 8 (enero-diciembre de 2022). ISSN: 2448-6663
dc.subjectBiosensor, ADN, electroquímica. DNA, electrochemistry.
dc.titleComparación biosensors electroquímico de ADN basados en matriz de grafito y SPE
dc.typeArtículo


Este ítem pertenece a la siguiente institución