dc.creatorDíaz Rodea, Sebastián
dc.creatorBarceló Quintal, Icela Dagmar; 21799
dc.creatorSolís Correa, Hugo Eduardo
dc.creatorGOMEZ SALAZAR, SERGIO; 121986
dc.creatorGiacoman Vallejos, German;#0000-0002-9792-6904
dc.creatorMENDEZ NOVELO, ROGER IVAN; 202806
dc.creatorDíaz Rodea, Sebastián
dc.creatorBarceló Quintal, Icela Dagmar
dc.creatorSolís Correa, Hugo Eduardo
dc.creatorGómez Salazar, Sergio
dc.creatorGiacomán Vallejo, Germán
dc.creatorMéndez Novelo, Roger Iván
dc.date.accessioned2023-01-11T17:14:09Z
dc.date.accessioned2023-07-20T16:16:43Z
dc.date.available2023-01-11T17:14:09Z
dc.date.available2023-07-20T16:16:43Z
dc.date.created2023-01-11T17:14:09Z
dc.date.issued2021
dc.identifierhttp://hdl.handle.net/11191/9278
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/7718329
dc.description.abstractLa generación de residuos sólidos urbanos (RSU) es un problema grave por las emisiones gaseosas y líquidas (lixiviados) que contienen sustancias peligrosas y de no controlarse contaminan suelos y cuerpos de agua. Actualmente los rellenos sanitarios tecnificados es una opción, por su tipo de construcción protegen al suelo y colectan los lixiviados mediante lagunas de oxidación, además de que estos líquidos pueden ser tratados. Su degradación puede ser mediante procesos de oxidación avanzada (POA’s) que contienen radicales fuertemente oxidantes como HO• y HOO•. En este trabajo se efectuaron las oxidaciones de los lixiviados del relleno sanitario del Centro Ecológico de Manejo Integral de Residuos Querétaro (CEMIRQ), primero por la reacción Fenton y se completó la degradación combinando Ozono-UV, obteniéndose una reducción de 14,421.63 mg/L desde la oxidación del lixiviado crudo hasta la oxidación O₃-UV, obteniéndose un 96.50% de eficiencia. Las cinéticas de la oxidación O₃-UV fueron de primer orden.
dc.description.abstractThe urban solid waste (MSW) is a serious problem due to gaseous and liquid emissions (leachates) that contain dangerous substances, if it’s not controlled, can be contaminate soils and water bodies. Currently, technified sanitary landfills are an option, due to their type of construction, they protect the soil and collect leachates through oxidation ponds, in addition to the fact that these liquids can be treated. Its degradation can be through advanced oxidation processes (POA's) that contain strongly oxidizing radicals such as HO • and HOO •. In this work the leachate oxidations from the sanitary landfill of the Ecological Center for Integral Waste Management Querétaro (CEMIRQ) were carried out, first by the Fenton reaction and the degradation was completed by combining Ozone-UV, obtaining a reduction of 14,421.63 mg / L from the oxidation of the crude leachate until the oxidation O₃-UV, obtaining a 96.50% efficiency. The kinetics O₃-UV oxidation were of the first order.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 7, número 7 (enero-diciembre de 2021). ISSN: 2448-6663
dc.subjectRelleno sanitario, lixiviados, oxidaciones avanzadas. Landfills, leachates, advanced oxidations.
dc.titleTratamiento del lixiviado de un relleno sanitario utilizando oxidaciones avanzadas combinadas
dc.typeArtículo


Este ítem pertenece a la siguiente institución