dc.description.abstractSegún el procedimiento técnico PR 17 -COES, se debe realizar ensayos de potencia efectiva y rendimiento en las Centrales Termoeléctricas, en todas sus configuraciones operativas posibles. La C.T. Chilca1, cuenta con 10 configuraciones operativas, pero se realizó solo un ensayo a ciclo combinado 3x1 del cual se pudo evaluar y determinar la potencia efectiva y rendimiento de las otras 09 configuraciones operativas. La metodología de la investigación utilizada en la presente tesis es del tipo tecnológica aplicada y de nivel correlacional, con el objetivo de hallar un tipo de correlación y una metodología de cálculo que permita determinar la potencia efectiva y rendimiento para las configuraciones operativas mencionadas de la C. T. Chilca1. Finalmente haciendo uso de un factor de corrección adicional de determina la potencia para las configuraciones de ciclo simple en las turbinas a gas y mediante una correlación múltiple lineal se logra determinar la potencia de la TV para cada configuración operativa de las configuraciones operativas restantes mencionadas. Los resultados fueron contrastados con lecturas reales obteniendo una variación promedio de 2.3%.
dc.description.abstractAccording to the technical process PR17-COES, tests should be performed effective power and performance in thermoelectric power stations, in all possible operating configurations. The C. T. Chilca1 has 10 operating configurations, but only one trial was conducted to 3x1 combined cycle which could evaluate and determine the effective power and performance to the other 09 operating configurations. The research methodology used in this thesis is the technology applied and correlational type level with the aim of finding a type of correlation and calculation methodology to determine the effective power and performance to the aforementioned operational configurations CT Chilca1. Finally making use of a correction factor determinad additional power for configurations in simple cycle gas turbines and by a linear multiple correlation is achieved determine the potency of the TV operating configuration for each of said remaining operating configurations. The results were compared with actual readings obtained an average change of 2.3%.
dc.languagespa
dc.publisherUniversidad Nacional del Callao
dc.publisherPE
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0/pe/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceUniversidad Nacional del Callao
dc.sourceRepositorio institucional - UNAC
dc.subjectThermoelectric Central
dc.subjectCombined cycle
dc.subjectEffective power
dc.subjectPerformance
dc.subjectGas and steam turbine
dc.subjectCorrelations
dc.subjectEssays
dc.subjectCentral Termoeléctricas
dc.subjectCiclo combinado
dc.subjectPotencia efectiva
dc.subjectRendimiento
dc.subjectTurbinas a gas y vapor
dc.subjectCorrelaciones
dc.subjectEnsayos
dc.titleCiclo combinado 3X1 de la central térmica Chilca 1 y su efecto en la potencia efectiva y rendimiento de las configuraciones operativas - Lima
dc.typeinfo:eu-repo/semantics/bachelorThesis


Este ítem pertenece a la siguiente institución