dc.contributor | De La Cruz Casaño, Rafael | |
dc.creator | Roque Chavez, Pedro Luis | |
dc.creator | Veliz Pastrana, Wilmer | |
dc.date.accessioned | 2023-01-13T19:30:20Z | |
dc.date.available | 2023-01-13T19:30:20Z | |
dc.date.created | 2023-01-13T19:30:20Z | |
dc.date.issued | 2022 | |
dc.identifier | Roque, P. y Veliz, W. (2022). Design of a forced internal convection dehydrator to improve the productivity of ginger (Zingiber officinnale) in Pichanaqui, Junín-Perú in 2021. Tesis para optar el titulo profesional de Ingeniero Mecánico, Escuela Académica Profesional de Ingeniería Mecánica, Universidad Continental, Huancayo, Perú. | |
dc.identifier | https://hdl.handle.net/20.500.12394/12277 | |
dc.identifier | International Journal of Mechanical Engineering and Robotics Research | |
dc.identifier | https://doi.org/10.18178/ijmerr.11.8.600-605 | |
dc.description.abstract | Abstract—This research work develops a forced internal
convection dehydrator to improve the productivity
regarding ginger dehydration in Pichanaqui and the
objective is to design an internal forced convection
dehydrator using a centrifugal fan to maximize the
productivity and to improve the quality of the dried ginger.
This research is based on the German design norm VDI 2221
which was adapted and complemented with the norm VDI
2225. Furthermore, it was added the state of the art and also
7 phases for the development of the objective. Those points
were implemented in order to determine the list of
requirements and desires, the abstraction process or black
box, the sequence of operations, a solution analysis or white
box, a morphology matrix, a technical economic analysis to
finally obtain a preliminary project. The results of the
mathematical modeling determined that for the feeding
system there is a hopper and a worm screw that doses and
transfers the fuel with a flow of 4.5 [kg/hour] to keep the
heat generated inside the combustion system, which is made
of 310 refractory stainless steel and vermiculite plate as
thermal insulator, with internal tubes that function as filters
and heat exchangers for the circulation system connected to
a rectangular duct that joins both rooms circulating at 9. 012
kg/min of air forced by a fan of 4750 m3
/h and with a
dehydration temperature of 59.89°C, production capacity of
274.47kh/day, made of 304 stainless steel and glass wool
insulation. | |
dc.language | eng | |
dc.publisher | Universidad Continental | |
dc.publisher | PE | |
dc.relation | http://www.ijmerr.com/index.php?m=content&c=index&a=show&catid=213&id=1780 | |
dc.rights | https://creativecommons.org/licenses/by/4.0/ | |
dc.rights | Attribution 4.0 International (CC BY 4.0) | |
dc.rights | Acceso abierto | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.source | Universidad Continental | |
dc.source | Repositorio Institucional - Continental | |
dc.subject | Diseño gráfico | |
dc.subject | Productividad | |
dc.title | Design of a forced internal convection dehydrator to improve the productivity of ginger (Zingiber officinnale) in Pichanaqui, Junín-Perú in 2021 | |