dc.creatorVivanco, Mónica
dc.creatorOlivera, Paula
dc.creatorLópez, Alcides
dc.creatorVargas, Johnny
dc.creatorCastro, Emma
dc.creatorRamos, Bertha
dc.creatorCastro, Emma
dc.creatorLópez, Alcides
dc.creatorRamos, Bertha
dc.creatorVargas, Johnny
dc.creatorVivanco, Mónica
dc.creatorOlivera, Paula
dc.date.accessioned2014-04-25T17:55:28Z
dc.date.accessioned2023-05-24T15:13:46Z
dc.date.available2014-04-25T17:55:28Z
dc.date.available2023-05-24T15:13:46Z
dc.date.created2014-04-25T17:55:28Z
dc.date.issued2014-01
dc.identifierCastro E, López A, Ramos B, Vargas J, Vivanco M, Olivera P. Caracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas. Informe Científico Tecnológico. 2012; Volumen 12, p. 99-106.
dc.identifier1684-1662
dc.identifierhttps://hdl.handle.net/20.500.13054/137
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/6442771
dc.description.abstractDebido a su excelente biocompatibilidad, bioactividad y osteoconducción, la hidroxiapatita es un material que se utiliza ampliamente en cirugía ortopédica, traumatología, odontología y cirugía maxilo-facial. El presente trabajo tiene como propósito caracterizar una biohidroxiapatita (BHA) esterilizada por radiación gamma y tratada a las dosis de 0, 25, 50, 100, 200 y 500 kGy, utilizando técnicas gravimétricas, espectroscopía FTIR, difracción de rayos X, fluorescencia de rayos X, microscopía electrónica de barrido y pruebas organolépticas. Se realizaron pruebas dosimétricas para la irradiación del producto y la esterilidad de la BHA se comprobó mediante pruebas microbiológicas. Los resultados de las pruebas de caracterización concluyen que la BHA irradiada a 25 kGy es apropiada para ser utilizada en aplicaciones médicas.
dc.description.abstractHydroxyapatite is a material that is used for orthopaedic surgery and traumatology as well as for odontology and maxilo-facial surgery due to its biocompatibility, bioactivity and osteoconduction. To be used in patients, hydroxyapatite must be sterile and thus, previously should undergo an sterilization process. This work aims to characterize a biohydroxyapatite (BHA) sterilized by gamma radiation, treated at doses of 25, 50, 100, 200 y 500 kGy, using gravimetric techniques, FT-IR spectroscopy, X-ray diffraction and fluorescence, scanning electron microscopy as well as organoleptic tests. For product irradiation, dosimetric tests were performed and the sterility of the product was verified through microbiological tests. Results of characterization tests concluded that the BHA irradiated at 25 kGy is appropriate for medical applications.
dc.languagespa
dc.publisherLima
dc.publisherPE
dc.rightsinfo:eu-repo/semantics/openAccess
dc.sourceInstituto Peruano de Energía Nuclear
dc.sourceRepositorio Institucional del Instituto Peruano de Energía Nuclear
dc.subjectHidroxiapatita
dc.subjectRadiación gamma
dc.subjectDosis de radiación
dc.titleCaracterización de una biohidroxiapatita tratada con radiación gamma para aplicaciones biomédicas
dc.typeinfo:eu-repo/semantics/article


Este ítem pertenece a la siguiente institución