info:eu-repo/semantics/article
MEDIDA DE LA IMPEDANCIA ACÚSTICA EN CONDUCTOS Y SILENCIADORES BAJO CONDICIONES DE BORDE DIFERENTES
Registro en:
10.4206/sint.tecnol.2005.v2n1-02
Autor
JURADO, CARLOS
ARENAS, JORGE
Institución
Resumen
This research presents details of a measurement system used to determine acoustical parameters for duct systems. In particular, the normal incidence reflection factor and the acoustic impedance were obtained theoretically and experimentally. The effect on the resulting parameters of factors such as air flow and duct curvature was investigated. It was found that the flow induced effect was equivalent to shortening the length of the duct carrying the flow. An empirical expression that predicts the equivalent length of the duct in terms of the flow Mach number is suggested. On the other hand, it was found that the acoustic input impedance of a curved duct is equal to the same parameter for a straight duct of length equal to the central axis of the curved duct. En este trabajo se presentan los detalles de un sistema de medida para la determinación de parámetros acústicos en sistemas de conductos. En particular, el factor de reflexión a incidencia normal y la impedancia acústica, fueron determinados teórica y experimentalmente. Se investigó el efecto en los resultados de factores como el flujo de aire y la curvatura en los conductos. Se encontró que el efecto del primero se traduce en una variación del largo equivalente del conducto que transporta flujo. Por otro lado, se encontró que la impedancia de entrada de un conducto curvado es igual al mismo parámetro para un conducto recto de largo igual al eje central del conducto curvado.