dc.contributorMesquita, Leonardo [UNESP]
dc.contributorReis, Luiz Octávio Mattos dos [UNESP]
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2022-08-22T12:51:41Z
dc.date.accessioned2022-12-20T14:31:11Z
dc.date.available2022-08-22T12:51:41Z
dc.date.available2022-12-20T14:31:11Z
dc.date.created2022-08-22T12:51:41Z
dc.date.issued2022-03-18
dc.identifierhttp://hdl.handle.net/11449/236239
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5416284
dc.description.abstractCom o aumento da demanda energia solar solicitada pelo mercado, a área da engenharia elétrica que visa estudar as tecnologias vinculadas aos controladores das placas fotovoltaicas vem em constante crescente, por conta disso, o estudo de sincronizadores de rede, ou Phase Locked Loop (PLL), está cada vez mais presente no cotidiano dos engenheiros eletricistas. Atualmente, um dos métodos mais utilizados para desenvolvimento de PLL se baseia na metodologia Synchronous Reference Frame (SRF), a qual se utiliza de ferramentas matemáticas como transformadas de Clarke e Park, Controlador PI, Filtro digitais FIR e a parametrização através do método Symmetrical Optimum (SO). Ao final, utilizando de maneira correta essas ferramentas, o PLL estará apto a identificar alterações de fase do sistema para condições diversas como mudança de amplitude de fase, presença de harmônicos e desequilíbrio de fase.
dc.description.abstractAs the demand for solar energy increases, the field of electrical engineering that focuses on the study of technologies related to photovoltaic plate controllers is constantly growing. Due to this, the study of grid synchronizers, or Phase Locked Loop (PLL), is becoming more and more present in the daily life of electrical engineers. Currently, one of the most used methods for developing PLL is based on the Synchronous Reference Frame (SRF) methodology, which uses mathematical tools such as Clarke and Park transforms, PI controller, FIR digital filters, and parameterization through the Symmetrical Optimum (SO) method. In the end, the PLL will be able to identify phase changes in the system for various conditions such as a change in phase amplitude, presence of harmonics, and phase unbalance.
dc.languagepor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rightsAcesso aberto
dc.subjectPlaca fotovoltaica
dc.subjectTransformada de Park
dc.subjectControlador PI
dc.subjectFiltro FIR
dc.subjectPLL
dc.subjectSistema de energia fotovoltaica
dc.subjectEnergia elétrica - Distribuição
dc.subjectEnergia solar
dc.subjectSymmetrical optimum
dc.subjectPhotovoltaic panel
dc.subjectPark's transform
dc.subjectPI controller
dc.subjectFIR filter
dc.titleValidação de um modelo matemático para um sincronizador de um painel fotovoltaico
dc.typeTesis


Este ítem pertenece a la siguiente institución