dc.contributorInst Hochenergiephys
dc.contributorUniv Antwerp
dc.contributorVrije Univ Brussel
dc.contributorUniv Libre Bruxelles
dc.contributorCatholic Univ Louvain
dc.contributorInst Rudjer Boskovic
dc.contributorUniv Helsinki
dc.contributorHelsinki Inst Phys
dc.contributorLappeenranta Lahti Univ Technol
dc.contributorUniv Strasbourg
dc.contributorUniv Lyon
dc.contributorRhein Westfal TH Aachen
dc.contributorDESY
dc.contributorUniv Hamburg
dc.contributorKIT
dc.contributorNCSR Demokritos
dc.contributorEotvos Lorand Univ
dc.contributorWigner Res Ctr Phys
dc.contributorInst Nucl Res ATOMKI
dc.contributorHBNI
dc.contributorUniv Delhi
dc.contributorSaha Inst Nucl Phys
dc.contributorIst Nazl Fis Nucl
dc.contributorUniv Bari
dc.contributorPolitecn Bari
dc.contributorUniv Catania
dc.contributorUniv Firenze
dc.contributorUniv Genoa
dc.contributorUniv Milano Bicocca
dc.contributorUniv Padua
dc.contributorUniv Bergamo
dc.contributorUniv Pavia
dc.contributorUniv Perugia
dc.contributorCNR IOM Perugia
dc.contributorUniv Pisa
dc.contributorScuola Normale Super Pisa
dc.contributorUniversit Torino
dc.contributorUniv Cantabria
dc.contributorEuropean Org Nucl Res
dc.contributorPaul Scherrer Inst
dc.contributorSwiss Fed Inst Technol
dc.contributorUniv Zurich
dc.contributorNatl Taiwan Univ NTU
dc.contributorUniv Bristol
dc.contributorRutherford Appleton Lab
dc.contributorImperial Coll
dc.contributorBrunel Univ
dc.contributorCatholic Univ Amer
dc.contributorBrown Univ
dc.contributorUniv Calif Davis
dc.contributorUniv Calif Riverside
dc.contributorUniv Calif San Diego
dc.contributorUniv Calif Santa Barbara
dc.contributorUniv Colorado
dc.contributorCornell Univ
dc.contributorFermilab Natl Accelerator Lab
dc.contributorFlorida State Univ
dc.contributorUniv Illinois Chicago UIC
dc.contributorUniv Iowa
dc.contributorJohns Hopkins Univ
dc.contributorUniv Kansas
dc.contributorKansas State Univ
dc.contributorUniv Mississippi
dc.contributorUniv Nebraska
dc.contributorSUNY Buffalo
dc.contributorNortheastern Univ
dc.contributorNorthwestern Univ
dc.contributorOhio State Univ
dc.contributorUniv Puerto Rico
dc.contributorPurdue Univ
dc.contributorPurdue Univ Northwest
dc.contributorRice Univ
dc.contributorUniv Rochester
dc.contributorRutgers State Univ
dc.contributorTexas A&M Univ
dc.contributorVanderbilt Univ
dc.contributorVienna Univ Technol
dc.contributorInst Theoret & Expt Phys
dc.contributorUniv Haute Alsace
dc.contributorChulalongkorn Univ
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorIndian Inst Sci IISc
dc.contributorUniv Debrecen
dc.contributorHoria Hulubei Natl Inst Phys & Nucl Engn IFIN HH
dc.contributorUniv Cagliari
dc.contributorShoolini Univ
dc.contributorBogazici Univ
dc.contributorInst Polytech Grenoble
dc.contributorTadeusz Kosciuszko Cracow Univ Technol
dc.contributorUniv Castilla La Mancha
dc.contributorUniv Patras
dc.contributorEcole Polytech Fed Lausanne
dc.contributorNatl Tech Univ Athens
dc.contributorUniv Wisconsin
dc.contributorCALTECH
dc.contributorBethel Univ
dc.contributorKaramanoglu Mehmetbey Univ
dc.contributorNanjing Normal Univ
dc.date.accessioned2021-06-25T11:52:43Z
dc.date.accessioned2022-12-19T22:50:31Z
dc.date.available2021-06-25T11:52:43Z
dc.date.available2022-12-19T22:50:31Z
dc.date.created2021-06-25T11:52:43Z
dc.date.issued2021-02-01
dc.identifierJournal Of Instrumentation. Bristol: Iop Publishing Ltd, v. 16, n. 2, 78 p., 2021.
dc.identifier1748-0221
dc.identifierhttp://hdl.handle.net/11449/209242
dc.identifier10.1088/1748-0221/16/02/P02027
dc.identifierWOS:000625188800023
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5389839
dc.description.abstractThe CMS detector at the CERN LHC features a silicon pixel detector as its innermost subdetector. The original CMS pixel detector has been replaced with an upgraded pixel system (CMS Phase-1 pixel detector) in the extended year-end technical stop of the LHC in 2016/2017. The upgraded CMS pixel detector is designed to cope with the higher instantaneous luminosities that have been achieved by the LHC after the upgrades to the accelerator during the first long shutdown in 2013-2014. Compared to the original pixel detector, the upgraded detector has a better tracking performance and lower mass with four barrel layers and three endcap disks on each side to provide hit coverage up to an absolute value of pseudorapidity of 2.5. This paper describes the design and construction of the CMS Phase-1 pixel detector as well as its performance from commissioning to early operation in collision data-taking.
dc.languageeng
dc.publisherIop Publishing Ltd
dc.relationJournal Of Instrumentation
dc.sourceWeb of Science
dc.subjectInstrumentation for particle accelerators and storage rings - high energy (linear accelerators, synchrotrons)
dc.subjectParticle tracking detectors
dc.subjectDetector design and construction technologies and materials
dc.subjectDetector alignment and calibration methods (lasers, sources, particle-beams)
dc.titleThe CMS Phase-1 pixel detector upgrade
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución