Influence of the biomaterial thickness in a dielectrically charged modulated fringing field bio-tunnel-FET device
Fecha
2020-04-01Registro en:
ECS Transactions, v. 97, n. 5, p. 109-114, 2020.
1938-5862
1938-6737
10.1149/09705.0109ecst
2-s2.0-85085866766
0496909595465696
0000-0002-0886-7798
Autor
Universidade de São Paulo (USP)
Universidade Estadual Paulista (Unesp)
Institución
Resumen
In this paper the influence of the biomaterial thickness (tBio) in a dielectrically charged modulated fringing field Bio-Tunnel FET is studied using TCAD simulation. The sensitivity of the biosensor TFET is observed in the ambipolar current region due to the variation of the dielectric permittivity and/or the presence of charges into the biomaterial. The results show that when tBioincreases from 10 nm to 30 nm, the sensitivity increases up to 2 orders of magnitude. The presence of positive fixed charges into the biomaterial also increases the sensitivity more than 1 order of magnitude in the studied charge magnitude range.