dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorFederal University of Alfenas (UNIFAL-MG)
dc.date.accessioned2019-10-06T16:12:40Z
dc.date.accessioned2022-12-19T18:44:36Z
dc.date.available2019-10-06T16:12:40Z
dc.date.available2022-12-19T18:44:36Z
dc.date.created2019-10-06T16:12:40Z
dc.date.issued2019-05-01
dc.identifierInternational Endodontic Journal, v. 52, n. 5, p. 689-700, 2019.
dc.identifier1365-2591
dc.identifier0143-2885
dc.identifierhttp://hdl.handle.net/11449/188579
dc.identifier10.1111/iej.13052
dc.identifier2-s2.0-85059581408
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5369617
dc.description.abstractAim: To evaluate the inflammatory response and ability to induce mineral deposition through histological and immunohistochemical analysis for osteocalcin (OCN), osteopontin (OPN) and bone sialoprotein (BSP) of a new calcium silicate-based cement, Bio-C Pulpo (Angelus), compared to white mineral trioxide aggregate (White MTA-Ang) (Angelus). Methodology: Polyethylene tubes containing Bio-C Pulpo and White MTA-Ang as well as empty tubes were implanted into the dorsal connective tissue of 30 Wistar rats, which were arranged in five groups according to the period of analysis: 7, 15, 30, 60 and 90 days. After each experimental period, the tubes with surrounding tissue were removed and histologically processed to be analysed using haematoxylin–eosin and immunohistochemistry for the detection of OCN, OPN and BSP. The data were statistically analysed (Friedman's test) at a 5% significance level. Results: The inflammatory response observed with Bio-C Pulpo and White MTA-Ang was greater after 7 and 15 days and decreased from 30 days onwards. No significant difference was found between the control, Bio-C Pulpo and White MTA-Ang at the different periods of analysis (P > 0.05). The immunolabelling for OCN, OPN and BSP was more intense for Bio-C Pulpo and White MTA-Ang after 60 and 90 days, but there was no difference between Bio-C Pulpo and White MTA-Ang at the different periods of analysis (P > 0.05). Conclusion: Bio-C Pulpo is biocompatible and induces immunolabelling of osteogenic markers such as OCN, OPN and BSP similar to White MTA-Ang.
dc.languageeng
dc.relationInternational Endodontic Journal
dc.rightsAcesso restrito
dc.sourceScopus
dc.subjectbiocompatibility
dc.subjectbone sialoprotein
dc.subjectosteocalcin
dc.subjectosteopontin
dc.subjectpulpotomy
dc.titleBiocompatibility and immunohistochemical evaluation of a new calcium silicate-based cement, Bio-C Pulpo
dc.typeArtículos de revistas


Este ítem pertenece a la siguiente institución