dc.contributorBorges, Paulo César
dc.contributorAlbano, Mauro Batista
dc.contributorBorges, Paulo César
dc.contributorReis, Ricardo Fernando dos
dc.contributorAlbano, Mauro
dc.creatorMendes, Guilherme Henseler Damaceno
dc.creatorAbdalla, Kalil Braz
dc.date.accessioned2020-11-12T18:28:10Z
dc.date.accessioned2022-12-06T15:05:46Z
dc.date.available2020-11-12T18:28:10Z
dc.date.available2022-12-06T15:05:46Z
dc.date.created2020-11-12T18:28:10Z
dc.date.issued2011-11-30
dc.identifierMENDES, Guilherme Henseler Damaceno; ABDALLA, Kalil Braz. Reconstrução do ligamento cruzado anterior com parafusos de interferência: pela técnica Transtibial e Outside In. 2011. 75 f. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Curitiba, 2011.
dc.identifierhttp://repositorio.utfpr.edu.br/jspui/handle/1/10308
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/5260728
dc.description.abstractThe methods that are currently used in the reconstruction anterior cruciate ligament of the knee show a use of high technologies, which makes them very expensive. That high value to perform the surgeries ends invalidating their applications in the public health in developing countries. The methods interference screws used to perform bone graft fixation have a value of relatively lower for surgery of reconstruction, because the screws are cheaper compared with the other techniques. Thus, 22 trials were performed biomechanical, comparing two different methods of Femoral fixation for cruciate ligament reconstruction previous fixations were made both with screw interference. Porcine femurs were used and digital ligaments of the foot of cattle to simulate the quadruple graft human knee flexors. The first group of 11 samples was done by the technique Transtibial and showed values of 541.7 N for the and maximum load 93.7 N / mm for rigidity. The second group of 11 samples was done by the technical and Outside in showed values of 533 N and 86.4 N / mm for stiffness. There was no significant difference in the maximum loads in the two trials, but the technique Transtibial values were 10% higher for the stiffness compared with the technique Outside in.
dc.publisherUniversidade Tecnológica Federal do Paraná
dc.publisherCuritiba
dc.publisherBrasil
dc.publisherEngenharia Mecânica
dc.publisherUTFPR
dc.rightsopenAccess
dc.subjectTecnologia médica
dc.subjectJoelhos - Ferimentos e lesões
dc.subjectMedical technology
dc.subjectKnee - Wounds and injuries
dc.titleReconstrução do ligamento cruzado anterior com parafusos de interferência: pela técnica Transtibial e Outside In
dc.typebachelorThesis


Este ítem pertenece a la siguiente institución