dc.description.abstract | Con el objetivo de evaluar la mejor remoción por electrocoagulación de los principales contaminantes del efluente de la planta piloto de leche ‘‘La Molina’’ se construyó un electrocoagulador a escala laboratorio. La configuración usada fue de 6 pares de electrodos Al-Fe conectados en paralelo con una configuración bipolar a una fuente de alimentación de corriente continua; el electrodo de Al funcionó como ánodo y el electrodo Fe como cátodo. El electrocoagulador tuvo una configuración de batch capaz de tratar 5,6 L de aguas residuales. Las mejores condiciones operacionales se alcanzaron bajo un pH de 8,5, tiempo 30 minutos e intensidad de corriente 3A. Usando estos resultados como el escenario más eficiente, el electrocoagulador redujo 45% de DQO, 42% de DBO5, 96.2% de fósforo total, sólidos suspendidos totales 78.8%, aceites y grasas más del 95%. Sin embargo, otros parámetros aumentaron como el nitrógeno amoniacal en 2.76 veces y el aluminio en 24.3. Además de generarse sólidos sedimentables que antes de aplicarse la electrocoagulación no había | |
dc.description.abstract | In order to evaluate the best removal by electrocoagulation of the main contaminants of the effluent of the pilot plant of '' La Molina '', a laboratory-scale electrocoagulator was constructed. The configuration used was 6 pairs of Al-Fe electrodes connected in parallel with a bipolar configuration to a DC power supply; The Al electrode functioned as anode and the Fe electrode as the cathode. The electrocoagulator had a batch configuration capable of treating 5.6 L of wastewater. The best operating conditions were achieved under a pH of 8.5, time 30 minutes and current intensity 3A. Using these results as the most efficient scenario, the electrocoagulator reduced 45% COD, 42% BOD5, 96.2% total phosphorus, total suspended solids 78.8%, oils and fats more than 95%. However, other parameters increased as ammoniacal nitrogen by 2.76 times and aluminum by 24.3 times. Furthermore sedimentable solids were generated which were not in the wastewater before electrocoagulation | |
dc.language | spa | |
dc.publisher | Universidad Nacional Agraria La Molina | |
dc.publisher | PE | |
dc.rights | https://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Plantas lecheras | |
dc.subject | Proyectos pilotos | |
dc.subject | Universidades | |
dc.subject | Efluentes | |
dc.subject | Tratamiento de aguas residuales | |
dc.subject | Coagulación | |
dc.subject | Campo eléctrico | |
dc.subject | Procesamiento | |
dc.subject | Contaminantes | |
dc.subject | pH | |
dc.subject | Evaluación | |
dc.subject | Perú | |
dc.subject | Remoción de contaminantes | |
dc.subject | Planta Piloto de Leche "La Molina" | |
dc.subject | Electrocoagulación | |
dc.title | Aplicación del método de electrocoagulación al efluente de la Planta Piloto de Leche "La Molina" | |
dc.type | info:eu-repo/semantics/bachelorThesis | |