artículo científico
Validation of Total Daily Energy Expenditure Calculated with Actiheart against Doubly Labeled Water Method in Costa Rican Schoolchildren
Fecha
2015-10Registro en:
2157-9458
10.4236/fns.2015.613125
Autor
Zamora Salas, Juan Diego
Laclé Murray, Adriana
Institución
Resumen
The purpose of this study was
to use the measurement of the PAEE taken from Actiheart in order
to calculate the TEE in Costa Rican schoolchildren, and at the same time, to determine the effec-
tiveness when it is compared against the TEE obtained by the DLW. A total of sixteen male schoo
l-
children were measured for their total daily energy expenditure (TEE) with the doubly labeled
water (DLW) technique. The TEE obtained by the Actiheart monitor was calculated and validated
against the DWL. The TEE was obtained adding the physical activity energy expenditure given by
the Actiheart, plus the basal metabolic rate, and the energy cost of growth. The Pearson’s
product
-
moment correlation coeffi
cient a
nd the paired t
-test sample were measured in order to identify
the association of the data and to evidence the differences between both measurements of TEE
respectively. The Lin’s concordance correlation coefficient and the Bland
-Altman plot evaluated
the
concordance of both methods. The correlation between the TEE obtained by DLW and the one
calculated by Actiheart was r
= 0.97, P < 0.001. The paired t
-test showed no significant differences
between both methods. Lin’s concordance correlation coefficient wa
s Cb = 0.99, classified as a
l-
most perfect. The study validated the TEE calculated with Actiheart against the TEE measured by
the DLW.