dc.creatorGallay, Pablo
dc.creatorRubianes, María Dolores
dc.creatorGutierrez, Fabiana Andrea
dc.creatorRivas, Gustavo Adolfo
dc.date.accessioned2021-02-12T12:45:17Z
dc.date.accessioned2022-10-15T10:55:56Z
dc.date.available2021-02-12T12:45:17Z
dc.date.available2022-10-15T10:55:56Z
dc.date.created2021-02-12T12:45:17Z
dc.date.issued2019-05
dc.identifierGallay, Pablo; Rubianes, María Dolores; Gutierrez, Fabiana Andrea; Rivas, Gustavo Adolfo; Avidin and glucose oxidase-non-covalently functionalized multi-walled carbon nanotubes: A new analytical tool for building a bienzymatic glucose biosensor; Wiley VCH Verlag; Electroanalysis; 31; 10; 5-2019; 1888-1894
dc.identifier1040-0397
dc.identifierhttp://hdl.handle.net/11336/125568
dc.identifier1521-4109
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4378048
dc.description.abstractWe report an innovative supramolecular architecture for bienzymatic glucose biosensing based on the non-covalently functionalization of multi-walled carbon nanotubes (MWCNTs) with two proteins, glucose oxidase (GOx) (to recognize glucose) and avidin (to allow the specific anchoring of biotinylated horseradish peroxidase (b-HRP)). The optimum functionalization was obtained by sonicating for 10 min 0.50 mg mL−1 MWCNTs in a solution of 2.00 mg mL−1 GOx+1.00 mg mL−1avidin prepared in 50 : 50 v/v ethanol/water. The sensitivity to glucose for glassy carbon electrodes (GCE) modified with MWCNTs-GOx-avidin dispersion and b-HRP (GCE/MWCNTs-GOx-avidin/b-HRP), obtained from amperometric experiments performed at −0.100 V in the presence of 5.0×10−4 M hydroquinone, was (4.8±0.3) μA mM−1 (r2=0.9986) and the detection limit was 1.2 μM. The reproducibility for 5 electrodes using the same MWCNTs/GOx-avidin dispersion was 4.0 %, while the reproducibility for 3 different dispersions and 9 electrodes was 6.0 %. The GCE/MWCNT-GOx-avidin/b-HRP was successfully used for the quantification of glucose in a pharmaceutical product and milk.
dc.languageeng
dc.publisherWiley VCH Verlag
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1002/elan.201900202
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/abs/10.1002/elan.201900202
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rightsAtribución-NoComercial-CompartirIgual 2.5 Argentina (CC BY-NC-SA 2.5 AR)
dc.subjectAVIDIN
dc.subjectBIENZYMATIC BIOSENSOR
dc.subjectGLUCOSE BIOSENSOR
dc.subjectGLUCOSE OXIDASE
dc.subjectMULTI-WALLED CARBON NANOTUBES
dc.subjectNON-COVALENT FUNCTIONALIZATION
dc.titleAvidin and glucose oxidase-non-covalently functionalized multi-walled carbon nanotubes: A new analytical tool for building a bienzymatic glucose biosensor
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución