dc.creator | Gallay, Pablo | |
dc.creator | Rubianes, María Dolores | |
dc.creator | Gutierrez, Fabiana Andrea | |
dc.creator | Rivas, Gustavo Adolfo | |
dc.date.accessioned | 2021-02-12T12:45:17Z | |
dc.date.accessioned | 2022-10-15T10:55:56Z | |
dc.date.available | 2021-02-12T12:45:17Z | |
dc.date.available | 2022-10-15T10:55:56Z | |
dc.date.created | 2021-02-12T12:45:17Z | |
dc.date.issued | 2019-05 | |
dc.identifier | Gallay, Pablo; Rubianes, María Dolores; Gutierrez, Fabiana Andrea; Rivas, Gustavo Adolfo; Avidin and glucose oxidase-non-covalently functionalized multi-walled carbon nanotubes: A new analytical tool for building a bienzymatic glucose biosensor; Wiley VCH Verlag; Electroanalysis; 31; 10; 5-2019; 1888-1894 | |
dc.identifier | 1040-0397 | |
dc.identifier | http://hdl.handle.net/11336/125568 | |
dc.identifier | 1521-4109 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4378048 | |
dc.description.abstract | We report an innovative supramolecular architecture for bienzymatic glucose biosensing based on the non-covalently functionalization of multi-walled carbon nanotubes (MWCNTs) with two proteins, glucose oxidase (GOx) (to recognize glucose) and avidin (to allow the specific anchoring of biotinylated horseradish peroxidase (b-HRP)). The optimum functionalization was obtained by sonicating for 10 min 0.50 mg mL−1 MWCNTs in a solution of 2.00 mg mL−1 GOx+1.00 mg mL−1avidin prepared in 50 : 50 v/v ethanol/water. The sensitivity to glucose for glassy carbon electrodes (GCE) modified with MWCNTs-GOx-avidin dispersion and b-HRP (GCE/MWCNTs-GOx-avidin/b-HRP), obtained from amperometric experiments performed at −0.100 V in the presence of 5.0×10−4 M hydroquinone, was (4.8±0.3) μA mM−1 (r2=0.9986) and the detection limit was 1.2 μM. The reproducibility for 5 electrodes using the same MWCNTs/GOx-avidin dispersion was 4.0 %, while the reproducibility for 3 different dispersions and 9 electrodes was 6.0 %. The GCE/MWCNT-GOx-avidin/b-HRP was successfully used for the quantification of glucose in a pharmaceutical product and milk. | |
dc.language | eng | |
dc.publisher | Wiley VCH Verlag | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1002/elan.201900202 | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://onlinelibrary.wiley.com/doi/abs/10.1002/elan.201900202 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.rights | Atribución-NoComercial-CompartirIgual 2.5 Argentina (CC BY-NC-SA 2.5 AR) | |
dc.subject | AVIDIN | |
dc.subject | BIENZYMATIC BIOSENSOR | |
dc.subject | GLUCOSE BIOSENSOR | |
dc.subject | GLUCOSE OXIDASE | |
dc.subject | MULTI-WALLED CARBON NANOTUBES | |
dc.subject | NON-COVALENT FUNCTIONALIZATION | |
dc.title | Avidin and glucose oxidase-non-covalently functionalized multi-walled carbon nanotubes: A new analytical tool for building a bienzymatic glucose biosensor | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |