dc.creatorGoicoechea, Hector Casimiro
dc.creatorOlivieri, Alejandro Cesar
dc.creatorTauler, Romà
dc.date.accessioned2020-05-13T14:18:05Z
dc.date.accessioned2022-10-15T09:37:51Z
dc.date.available2020-05-13T14:18:05Z
dc.date.available2022-10-15T09:37:51Z
dc.date.created2020-05-13T14:18:05Z
dc.date.issued2010-01
dc.identifierGoicoechea, Hector Casimiro; Olivieri, Alejandro Cesar; Tauler, Romà; Application of the correlation constrained multivariate curve resolution alternating least-squares method for analyte quantitation in the presence of unexpected interferences using first-order instrumental data; Royal Society of Chemistry; Analyst; 135; 3; 1-2010; 636-642
dc.identifier0003-2654
dc.identifierhttp://hdl.handle.net/11336/105024
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4371229
dc.description.abstractCorrelation constrained multivariate curve resolution-alternating least-squares is shown to be a feasible method for processing first-order instrumental data and achieve analyte quantitation in the presence of unexpected interferences. Both for simulated and experimental data sets, the proposed method could correctly retrieve the analyte and interference spectral profiles and perform accurate estimations of analyte concentrations in test samples. Since no information concerning the interferences was present in calibration samples, the proposed multivariate calibration approach including the correlation constraint facilitates the achievement of the so-called second-order advantage for the analyte of interest, which is known to be present for more complex higher-order richer instrumental data. The proposed method is tested using a simulated data set and two experimental data systems, one for the determination of ascorbic acid in powder juices using UV-visible absorption spectral data, and another for the determination of tetracycline in serum samples using fluorescence emission spectroscopy.
dc.languageeng
dc.publisherRoyal Society of Chemistry
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/http://dx.doi.org/10.1039/b922547a
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://pubs.rsc.org/en/content/articlelanding/2010/an/b922547a#!divAbstract
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectMCR
dc.subjectALS
dc.subjectSecond order
dc.subjectFirst order
dc.titleApplication of the correlation constrained multivariate curve resolution alternating least-squares method for analyte quantitation in the presence of unexpected interferences using first-order instrumental data
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución