Impedance pletismography: variability of vascular response to suprasystolic injury

dc.creatorFeldman, Gabriela
dc.creatorHerrera de Olivera, Myriam Cristina
dc.date.accessioned2020-04-22T16:23:47Z
dc.date.accessioned2022-10-15T06:36:58Z
dc.date.available2020-04-22T16:23:47Z
dc.date.available2022-10-15T06:36:58Z
dc.date.created2020-04-22T16:23:47Z
dc.date.issued2003-03
dc.identifierFeldman, Gabriela; Herrera de Olivera, Myriam Cristina; Técnica impedancimétrica: variabilidad de la respuesta vascular ante apremio suprasistólico; Federación Argentina de Cardiología; Revista de la Federación Argentina de Cardiología; 32; 3-2003; 254-258
dc.identifier0326-646X
dc.identifierhttp://hdl.handle.net/11336/103301
dc.identifier1666-5694
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4356060
dc.description.abstractPara la valoración de la respuesta vascular, que condiciona un perfil de riesgo cardiovascular, han sido utilizados diferentes m étodos, tanto invasivos como no invasivos. Con el objetivo de determinar la variabilidad y la reproducibilidad de la respuesta vascular al apremio suprasistólico por pletismografía de impedancia, se ingresó un total de 7 individuos voluntarios, sin criterios de exclusión. Se realizó registro continuo pre, intra y post apremio suprasistólico y se determinó el comportamiento cada 30 segundos, incluyendo hasta 3 minutos post desoclusión. La prueba se repitió, con iguales condiciones, a los 30 minutos. Los resultados fueron evaluados por operadores independientes. Se comprobó que las medias de la población fueron reproducibles entre las dos repeticiones, las diferencias de medias fueron similares entre las repeticiones, y el perfil de comportamiento temporal fue igual entre las dos repeticiones. Se concluye que la técnica propuesta parece ser altamente sensible y repetible y brinda información con respecto al comportamiento vascular temporal.
dc.description.abstractDifferent methods, invasive and non-invasive, have been used to assess vascular response. This response determines cardiovascular risk profile. In order to ascertain variability and reproducibility of vascular response to suprasystolic injury by impedance pletismography, seven voluntary subjects were included in the study, without any exclusion criteria. A continuous register of pre-, intra-, and post-test was performed and behaviour was determined every 30 seconds, including even 3 minutes post-desocclusion. The test was performed again with the same conditions after 30 minutes. The findings were that the population means were reproducible among both repetitions, the differences of the means were similar among the repetitions and the temporal behaviour profile was the same between both repetitions. It is possible to conclude that the proposed technique seems to be highly sensitive and repeatable, and it brings information about the temporal vascular behaviour.
dc.languagespa
dc.publisherFederación Argentina de Cardiología
dc.relationinfo:eu-repo/semantics/altIdentifier/url/http://www.fac.org.ar/1/revista/03v32n2/artorig/arorig09/feldman.php
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectÓXIDO NITRICIO
dc.subjectHIPEREMIA REACTIVA
dc.subjectIMPEDANCIMETRÍA
dc.titleTécnica impedancimétrica: variabilidad de la respuesta vascular ante apremio suprasistólico
dc.titleImpedance pletismography: variability of vascular response to suprasystolic injury
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución