info:eu-repo/semantics/article
Voltammetric quantification of 4-nitrophenol using a multivariate optimized plated bismuth film electrode
Fecha
2019-07Registro en:
Núñez, Rodrigo Nicolás; Moreno Betancourth, Jessica María; Ortiz, Patricia Ines; Pfaffen, Maria Valeria del Valle; Voltammetric quantification of 4-nitrophenol using a multivariate optimized plated bismuth film electrode; American Chemical Society; Industrial & Engineering Chemical Research; 58; 27; 7-2019; 12411-12418
0888-5885
CONICET Digital
CONICET
Autor
Núñez, Rodrigo Nicolás
Moreno Betancourth, Jessica María
Ortiz, Patricia Ines
Pfaffen, Maria Valeria del Valle
Resumen
In this study the multivariate optimization of bismuth film deposition (BiFE) on glassy carbon electrode, together with square wave voltammetry parameters for nitrophenol quantification, is described for the first time. For this purpose, response surface methodology and desirability function were applied to a Box-Behnken design. For the BiFE deposition procedure, the relationship between the reduction current peak (ip) and standard deviation values with time, potential deposition, and Bi(III) concentration were analyzed; meanwhile, for frequency, step, and amplitude only the relationship with ip was considered. The pH influence in nitrophenol determination was carried on by univariate analysis. After parameters optimization a limit of detection of 3.4 × 10-6 mol L-1 was observed.