dc.creatorPiccirilli, Gisela Noemi
dc.creatorEscandar, Graciela Monica
dc.date.accessioned2021-07-26T15:02:22Z
dc.date.accessioned2022-10-15T01:54:09Z
dc.date.available2021-07-26T15:02:22Z
dc.date.available2022-10-15T01:54:09Z
dc.date.created2021-07-26T15:02:22Z
dc.date.issued2007-10
dc.identifierPiccirilli, Gisela Noemi; Escandar, Graciela Monica; A novel flow-through fluorescence optosensor for the determination of thiabendazole; Elsevier Science; Analytica Chimica Acta; 601; 2; 10-2007; 196-203
dc.identifier0003-2670
dc.identifierhttp://hdl.handle.net/11336/136930
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4332319
dc.description.abstractThis paper presents the development of a new flow-injection system combined with solid-surface fluorescence detection for the determination of the widely used fungicide thiabendazole. Nylon powder was probed as a novel solid support for building the optosensor. The method is based on the on-line immobilization of thiabendazole onto nylon in a continuous flow system, followed by the measurement of its native fluorescence. Aqueous samples are directly injected in a water carrier, resulting in a very simple and economical method. The analytical figures of merit obtained using 1500 μL of sample and 75% methanol (v/v) as eluting solution were: linear calibration range from 8 to 120 ng mL-1 (the lowest value corresponds to the quantitation limit), relative standard deviation, 0.9% (n = 5) at a level of 64 ng mL-1, limit of detection calculated according to 1995 IUPAC recommendations is to 2.8 ng mL-1, and sampling rate of 14 samples h-1. The potential interference from other agrochemicals, metal ions and common anions, and the viability of determining thiabendazole in real water samples were also evaluated.
dc.languageeng
dc.publisherElsevier Science
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267007013931
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2007.08.028
dc.rightshttps://creativecommons.org/licenses/by-nc-sa/2.5/ar/
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectFLUORESCENCE OPTOSENSOR
dc.subjectNYLON POWDER
dc.subjectTHIABENDAZOLE
dc.titleA novel flow-through fluorescence optosensor for the determination of thiabendazole
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución