dc.creator | Piccirilli, Gisela Noemi | |
dc.creator | Escandar, Graciela Monica | |
dc.date.accessioned | 2021-07-26T15:02:22Z | |
dc.date.accessioned | 2022-10-15T01:54:09Z | |
dc.date.available | 2021-07-26T15:02:22Z | |
dc.date.available | 2022-10-15T01:54:09Z | |
dc.date.created | 2021-07-26T15:02:22Z | |
dc.date.issued | 2007-10 | |
dc.identifier | Piccirilli, Gisela Noemi; Escandar, Graciela Monica; A novel flow-through fluorescence optosensor for the determination of thiabendazole; Elsevier Science; Analytica Chimica Acta; 601; 2; 10-2007; 196-203 | |
dc.identifier | 0003-2670 | |
dc.identifier | http://hdl.handle.net/11336/136930 | |
dc.identifier | CONICET Digital | |
dc.identifier | CONICET | |
dc.identifier.uri | https://repositorioslatinoamericanos.uchile.cl/handle/2250/4332319 | |
dc.description.abstract | This paper presents the development of a new flow-injection system combined with solid-surface fluorescence detection for the determination of the widely used fungicide thiabendazole. Nylon powder was probed as a novel solid support for building the optosensor. The method is based on the on-line immobilization of thiabendazole onto nylon in a continuous flow system, followed by the measurement of its native fluorescence. Aqueous samples are directly injected in a water carrier, resulting in a very simple and economical method. The analytical figures of merit obtained using 1500 μL of sample and 75% methanol (v/v) as eluting solution were: linear calibration range from 8 to 120 ng mL-1 (the lowest value corresponds to the quantitation limit), relative standard deviation, 0.9% (n = 5) at a level of 64 ng mL-1, limit of detection calculated according to 1995 IUPAC recommendations is to 2.8 ng mL-1, and sampling rate of 14 samples h-1. The potential interference from other agrochemicals, metal ions and common anions, and the viability of determining thiabendazole in real water samples were also evaluated. | |
dc.language | eng | |
dc.publisher | Elsevier Science | |
dc.relation | info:eu-repo/semantics/altIdentifier/url/https://www.sciencedirect.com/science/article/abs/pii/S0003267007013931 | |
dc.relation | info:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.1016/j.aca.2007.08.028 | |
dc.rights | https://creativecommons.org/licenses/by-nc-sa/2.5/ar/ | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.subject | FLUORESCENCE OPTOSENSOR | |
dc.subject | NYLON POWDER | |
dc.subject | THIABENDAZOLE | |
dc.title | A novel flow-through fluorescence optosensor for the determination of thiabendazole | |
dc.type | info:eu-repo/semantics/article | |
dc.type | info:ar-repo/semantics/artículo | |
dc.type | info:eu-repo/semantics/publishedVersion | |