dc.creatorMaxit, Luciano Alejandro
dc.creatorPolich, Francisco
dc.creatorCarballo, Roberto Esteban
dc.creatorBotterón, Fernando
dc.date.accessioned2022-10-11T10:19:45Z
dc.date.accessioned2022-10-15T00:19:59Z
dc.date.available2022-10-11T10:19:45Z
dc.date.available2022-10-15T00:19:59Z
dc.date.created2022-10-11T10:19:45Z
dc.date.issued2021-06
dc.identifierMaxit, Luciano Alejandro; Polich, Francisco; Carballo, Roberto Esteban; Botterón, Fernando; Estrategia de control por curva de caída con reducido costo computacional para inversores monofásicos en paralelo; Universidad Nacional de Misiones. Facultad de Ingeniería; +Ingenio; 3; 1; 6-2021; 87-115
dc.identifier2683-7021
dc.identifierhttp://hdl.handle.net/11336/172335
dc.identifier2618-5520
dc.identifierCONICET Digital
dc.identifierCONICET
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4324059
dc.description.abstractSe propone una estrategia de control por curva de caída con reducido costo computacional y elevada robustez ante incertezas paramétricas para inversores monofásicos en paralelo, utilizando un lazo de impedancia virtual para lograr una característica predominantemente inductiva a frecuencia fundamental. Todas estas características se consiguen utilizando un simple controlador integral en el lazo de control de tensión, del cual se analizan los límites de la ganancia integral para determinar la robustez del sistema ante la variación de la inductancia del filtro LC. La utilización de una característica inductiva a baja frecuencia hace que aparezca un valor de CC en la corriente del inductor del filtro LC, la cual produce pérdidas adicionales en este componente. Para solventar este problema, se propone eliminar esta componente CC mediante la modificación de la característica de la impedancia de salida a baja frecuencia. Se presentan resultados de simulación que validan la presente propuesta.
dc.description.abstractA droop control strategy is proposed using a virtual impedance loop to achieve a predominantly inductive output impedance at the fundamental frequency. The reduced computational cost at implementing the strategy is achieved by using a simple integral controller in the voltage control loop. Additionally, an analysis of the gain limits of this controller is done by means of the study of the system's robustness, varying the inductance of the LC filter. The emergence of a DC value at the inductor current is also examined, a problem that arises by the use of an inductive characteristic at low frequency. That DC value produces additional losses in the inductor. A simple solution is proposed to eliminate this problem by modifying the characteristic of the output impedance at low frequency. Simulation results validate this proposal.
dc.languagespa
dc.publisherUniversidad Nacional de Misiones. Facultad de Ingeniería
dc.relationinfo:eu-repo/semantics/altIdentifier/url/https://revistas.fio.unam.edu.ar/index.php/masingenio/article/view/264/695
dc.relationinfo:eu-repo/semantics/altIdentifier/doi/https://doi.org/10.36995/j.masingenio.2021.03.01.008
dc.rightshttps://creativecommons.org/licenses/by/2.5/ar/
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectCONTROL DIGITAL
dc.subjectCORRIENTE CONTINUA EN INDUCTORES
dc.subjectCONTROL POR CURVA DE CAIDA
dc.subjectPARALELISMO DE INVERSORES
dc.subjectREDUCIDO COSTO COMPUTACIONAL
dc.subjectINVERSOR MONOFASICO
dc.subjectIMPEDANCIA VIRTUAL
dc.titleEstrategia de control por curva de caída con reducido costo computacional para inversores monofásicos en paralelo
dc.typeinfo:eu-repo/semantics/article
dc.typeinfo:ar-repo/semantics/artículo
dc.typeinfo:eu-repo/semantics/publishedVersion


Este ítem pertenece a la siguiente institución