Quality control of ethyl alcohol

dc.creatorSolá, Nancy Haydée
dc.date2009-02-11T02:00:00Z
dc.date1995
dc.date.accessioned2017-03-08T20:09:10Z
dc.date.available2017-03-08T20:09:10Z
dc.identifierhttp://hdl.handle.net/10915/7080
dc.identifierhttp://www.latamjpharm.org/trabajos/14/3/LAJOP_14_3_2_1_CW3MRSOXDX.pdf
dc.identifierhttp://sedici.unlp.edu.ar/handle/10915/7080
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/429147
dc.descriptionLa comercialización y fraccionamiento del alcohol etilico está regido por un importante número de leyes y decretos. En el laboratorio de control de calidad, el profesional debe optimizar las técnicas de análisis para que se pueda cumplir con lo establecido en ellos. El objetivo de este trabajo es advertir sobre la presencia de una impureza, el acetal, regularmente presente en el alcohol etílico, que eluye junto al metanol y cuya concentración es necesario cuantificar correctamente, dada su gran toxicidad. Para ello se analiza el problema presentado cuando se trabaja en cromatografia gaseosa con una columna capilar tipo Carbowax 20 M, en las condiciones de trabajo sugeridas por IRAM. Para una correcta identificación de acetal fue necesario realizar dos cromatogramas, usando una columna polar y una no polar. En estas condiciones se puede apreciar claramente la presencia del acetal, que por no tener grupos hidroxilo libres presenta un comportamiento distinto al metanol en una columna no polar (Crosslinked 5% Ph Me Silicone)
dc.descriptionThe bottling and commercialization of ethyl alcohol is ruled by many laws and decrees. Therefore the chemists at quality control departments have to develop and improve the analytical methods in order to fulfil the legal previsions. The aim of the present paper is to put on guard about the presence of acetal, an impurity usually present in ethanol that elutes together with methanol and whose concentration should be carefully quantified, because of its high toxicity. Gas cromatography is one of the analytical methods sugested by IRAM for these purposes. This paper intends to point out that using a High Perfomance Capillary Column HP-20M , methanol and acetal retention times are so close that no peak separation is observable at this operating condition. This can be solved by using both polar and non polar columns.
dc.languagees
dc.relationActa Farmacéutica Bonaerense
dc.relationvol. 14, no. 3
dc.subjectacetal; alcohol etílico; cromatografía gaseosa
dc.subjectacetal; ethyl alcohol; gas chromatography
dc.subjectFarmacia
dc.subjectCromatografía
dc.subjectAlcoholes
dc.titleControl de calidad del alcohol etílico
dc.titleQuality control of ethyl alcohol