dc.creatorRomero Coronel, Graciela
dc.creatorLópez Andrade, Álvaro
dc.creatorCruz Martínez, Guillermo Antonio
dc.creatorRomero Coronel, Graciela
dc.creatorLópez Andrade, Álvaro
dc.creatorCruz Martínez, Guillermo Antonio
dc.date.accessioned2022-05-06T19:01:54Z
dc.date.accessioned2022-10-14T13:49:33Z
dc.date.available2022-05-06T19:01:54Z
dc.date.available2022-10-14T13:49:33Z
dc.date.created2022-05-06T19:01:54Z
dc.date.issued2015
dc.identifierhttp://hdl.handle.net/11191/8790
dc.identifier.urihttps://repositorioslatinoamericanos.uchile.cl/handle/2250/4239319
dc.description.abstractEl proyecto de la presente investigación, involucra la elaboración de electrodos en base a la sustitución del catalizador de un biosensor por plata metálica y hacer selectivo al electrodo para halogenuros y pseudohalogenuros, empleando el sistema de compósito a un procedimiento potenciométrico. El funcionamiento de los electrodos alternativos Compósito-Plata elaborados se comparó con un electrodo comercial. Las pruebas experimentales se realizaron con dos diferentes electrodos Compósito-Ag “A” y “B” y se realizaron siete titulaciones potenciométricas a microescala de alícuotas de 2.0 mL de KCN 0.01M, con AgNO₃ 0.01 M, midiendo el potencial simultáneamente del electrodo prototipo y el electrodo comercial conectados independientemente cada uno a un potenciómetro. Los resultados del análisis estadístico para ambos electrodos (llamados A y B) resultaron menores que los que establece el análisis de varianza para 95 % de probabilidad, lo que significa que es factible la utilización de esta tecnología para su aplicación al análisis químico cuantitativo.
dc.description.abstractThe project of this research involves the development of electrodes based on the replacement of the catalyst of a biosensor for metallic silver and make selective electrode for pseudohalides halide and using the composite system to a potentiometric method. The operation of the alternative Composito-Silver electrodes prepared was compared with a commercial electrode. Experimental tests were performed with two different electrodes Composito-Ag "A" and "B" seven potentiometric titrations were performed microscale 2.0 mL aliquots of 0.01M KCN with AgNO₃ 0.01 M, simultaneously measuring the electrode potential prototype commercial electrode independently each connected to a potentiometer. The results of statistical analysis to both electrodes (called A and B) were lower than those established by the analysis of variance for 95% probability, which means that the use of this technology is feasible for application to quantitative chemical analysis.
dc.languagespa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.rightshttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.rightsopenAccess
dc.rightsAtribución-NoComercial-SinDerivadas
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 1, número 1 (enero-diciembre de 2015). ISSN: 2448-6663
dc.subjectCompósito, pseudohalogenuros, potenciometría. Composite, pseudohalides, potentiometry.
dc.titleElaboración de electrodos prototipo basados en compósito para potenciometría de halogenuros y pseudohalogenuros
dc.typeArtículo


Este ítem pertenece a la siguiente institución