dc.contributorUniversidade Federal de São Paulo (UNIFESP)
dc.contributorSanta Casa Univ Hosp
dc.contributorUniversidade de São Paulo (USP)
dc.creatorMimica, M. J.
dc.creatorBerezin, Eitan Naaman [UNIFESP]
dc.creatorCarvalho, R. L. B.
dc.creatorMimica, I. M.
dc.creatorMimica, L. M. J.
dc.creatorSafadi, Marco Aurelio Palazzi [UNIFESP]
dc.creatorSchneider, E.
dc.creatorCaiaffa-Filho, H. H.
dc.date.accessioned2018-06-15T14:04:33Z
dc.date.accessioned2022-10-07T20:56:37Z
dc.date.available2018-06-15T14:04:33Z
dc.date.available2022-10-07T20:56:37Z
dc.date.created2018-06-15T14:04:33Z
dc.date.issued2007-08-01
dc.identifierBrazilian Journal Of Infectious Diseases. Salvador: Contexto, v. 11, n. 4, p. 415-417, 2007.
dc.identifier1413-8670
dc.identifierhttp://repositorio.unifesp.br/11600/42880
dc.identifierS1413-86702007000400009.pdf
dc.identifierS1413-86702007000400009
dc.identifier10.1590/S1413-86702007000400009
dc.identifierWOS:000254388600009
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/4025144
dc.description.abstractWe evaluated the performance of several methods for the detection of methicillin resistance in Staphylococcus aureus using 101 clinical S. aureus isolates from pediatric patients in a tertiary hospital in Brazil; 50 isolates were mecA-positive and 51 were mecA-negative. The Etest and oxacillin agar screening plates were 100% sensitive and specific for mecA presence. Oxacillin and cefoxitin disks gave sensitivities of 96 and 92%, respectively, and 98% specificity. Alterations of CLSI cefoxitin breakpoints increased sensitivity to 98%, without decreasing specificity. Our results highlight the importance of a continuing evaluation of the recommended microbiological methods by different laboratories and in different settings. If necessary, laboratories should use a second test before reporting a strain as susceptible, especially when testing strains isolated from invasive or serious infections. With the new (2007) CLSI breakpoints, the cefoxitin-disk test appears to be a good option for the detection of methicillin resistance in S. aureus.
dc.languageeng
dc.publisherContexto
dc.relationBrazilian Journal Of Infectious Diseases
dc.rightsAcesso aberto
dc.subjectMRSA
dc.subjectdisc diffusion
dc.subjectcefoxitin
dc.subjectmecA
dc.titleDetection of methicillin resistance in Staphylococcus aureus isolated from pediatric patients: Is the cefoxitin disk diffusion test accurate enough?
dc.typeArtigo


Este ítem pertenece a la siguiente institución