dc.contributorCosta, Yuri Daniel Jatobá
dc.contributor
dc.contributorhttp://lattes.cnpq.br/3826575172035095
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6737841388506901
dc.contributorCosta, Carina Maia Lins
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6483888857335060
dc.contributorCunha, Renato
dc.contributor
dc.contributorhttp://lattes.cnpq.br/4531085012970834
dc.creatorSantos, Fabiana Alves dos
dc.date.accessioned2014-11-18
dc.date.accessioned2014-12-17T14:48:18Z
dc.date.accessioned2022-10-06T13:58:47Z
dc.date.available2014-11-18
dc.date.available2014-12-17T14:48:18Z
dc.date.available2022-10-06T13:58:47Z
dc.date.created2014-11-18
dc.date.created2014-12-17T14:48:18Z
dc.date.issued2013-12-16
dc.identifierSANTOS, Fabiana Alves dos. PERFORMANCE OF A SPACED PILES WALL, ANCHORED BY TIEBACKS, IN SAND. 2013. 167 f. Dissertação (Mestrado em MECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS) - Universidade Federal do Rio Grande do Norte, Natal, 2013.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/14859
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3974102
dc.description.abstractIt is presented the analysis of a retaining wall designed for the basement of a residential building, located in Natal/RN, which consists in a spaced pile wall, anchored by tiebacks, in sand. This structure was instrumented in order to measure the wall s horizontal movements and the load distribution throughout the anchor fixed length. The horizontal movements were measured with an inclinometer, and the loads in the anchors were measured with strain gages, installed in three places throughout the anchor fixed length. Measurements for displacement were done right after the implementation of each stage of the building and right after the conclusion of the building, and the measurements for loads in the anchors were done during the performance test, at the moment of the locking off and, also, right after the conclusion of the building. From the data of displacement were obtained velocity and acceleration data of wall. It was found that the time elapsed on braced installation was decisive in the magnitude of the displacements. The maximum horizontal displacement of wall ranged between 0,18 and 0,66% of the final depth of excavation. The loads in the anchors strongly reduced to approximately half the anchor fixed length, followed an exponential distribution. Furthermore, it was found that there was a loss of load in the anchors over time, reaching 50% loss in one of them
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBR
dc.publisherUFRN
dc.publisherPrograma de Pós-Graduação em Engenharia Civil
dc.publisherMECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS
dc.rightsAcesso Aberto
dc.subjectEstrutura de contenção. Instrumentação. Tirantes
dc.subjectRetaining wall. Instrumentation. Anchors
dc.titleAvaliação do desempenho de uma cortina de estacas espaçadas, atirantada, em areia
dc.typemasterThesis


Este ítem pertenece a la siguiente institución