dc.contributorCosta, Yuri Daniel Jatobá
dc.contributor
dc.contributorhttp://lattes.cnpq.br/4896684382798679
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6737841388506901
dc.contributorCosta, Carina Maia Lins
dc.contributor
dc.contributorhttp://lattes.cnpq.br/6483888857335060
dc.contributorSales, Maurício Martines
dc.contributor
dc.contributorhttp://lattes.cnpq.br/2033708685029423
dc.creatorAraújo, Arthur Gomes Dantas de
dc.date.accessioned2014-06-26
dc.date.accessioned2014-12-17T14:48:16Z
dc.date.accessioned2022-10-06T13:33:00Z
dc.date.available2014-06-26
dc.date.available2014-12-17T14:48:16Z
dc.date.available2022-10-06T13:33:00Z
dc.date.created2014-06-26
dc.date.created2014-12-17T14:48:16Z
dc.date.issued2013-12-10
dc.identifierARAÚJO, Arthur Gomes Dantas de. Static Lateral loading tests on CFA bored piles and metalic driven piles in cohesionless soil. 2013. 253 f. Dissertação (Mestrado em MECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS) - Universidade Federal do Rio Grande do Norte, Natal, 2013.
dc.identifierhttps://repositorio.ufrn.br/jspui/handle/123456789/14852
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3970229
dc.description.abstractAn experimental study has been conducted to investigate the behavior of continuous flight auger (cfa) bored piles and metalic driven H-section piles under lateral loading in cohesionless soils. The piles were tested in two different areas at the same site. Both areas consisted of a 3-m thick compacted superficial fill of pure fine sand, underlain by layers of naturally occurring pure fine-thick sand. Fills are differentiated by the relative densities which were compressed, 45% e 70%, respectively. Each area received one identical pair of cfa piles and two identical pairs of H-piles. A static lateral loading test was performed in each pair of piles. In this work, the pile load test results are reported and interpreted. The horizontal coefficient of subgrade reaction was determined from the results of the loading tests and compared with values determined by correlations based on penetration resistance index of SPT tests (NSPT). p-y formulations describing the static behavior of the piles were applied to the problem under evaluation. Back Analyses were made through theoretical and experimental p-y curves for obtaining input parameters for the analytic models, among which the coefficient of horizontal reaction. The soil pile system horizontal loading at rupture was determined by the theoretical methods and the results were compared with the experimental results, checking its validity
dc.publisherUniversidade Federal do Rio Grande do Norte
dc.publisherBR
dc.publisherUFRN
dc.publisherPrograma de Pós-Graduação em Engenharia Civil
dc.publisherMECÂNICA DAS ESTRUTURAS, ESTRUTURAS DE CONCRETO E ALVENARIA E MATERIAIS E PROCESSOS CONSTRUTIVOS
dc.rightsAcesso Aberto
dc.subjectCoeficiente de reação horizontal. Curva p-y. Carregamento lateral. Areia
dc.subjectHorizontal coefficient of subgrade reaction. P-y curve. Lateral loading. Sand
dc.titleProvas de carga estática com carregamento lateral em estacas escavadas hélice contínua e cravadas metálicas em areia
dc.typemasterThesis


Este ítem pertenece a la siguiente institución