dc.contributor | Lima, Carlos Magno de | |
dc.contributor | | |
dc.contributor | http://lattes.cnpq.br/2845031630833781 | |
dc.contributor | | |
dc.contributor | http://lattes.cnpq.br/2682764296612645 | |
dc.contributor | Costa Júnior, João Carlos Arantes | |
dc.contributor | | |
dc.contributor | http://lattes.cnpq.br/5028446242533356 | |
dc.contributor | Abreu, Carlos Alexandre Camargo de | |
dc.contributor | | |
dc.contributor | http://lattes.cnpq.br/4827318749308538 | |
dc.contributor | Silva, Edjane Fabiula Buriti da | |
dc.contributor | | |
dc.contributor | http://lattes.cnpq.br/1736653643786951 | |
dc.creator | Saldanha, Artur Henrique Souza | |
dc.date.accessioned | 2017-09-06T22:40:36Z | |
dc.date.accessioned | 2022-10-06T13:30:25Z | |
dc.date.available | 2017-09-06T22:40:36Z | |
dc.date.available | 2022-10-06T13:30:25Z | |
dc.date.created | 2017-09-06T22:40:36Z | |
dc.date.issued | 2017-07-17 | |
dc.identifier | SALDANHA, Artur Henrique Souza. Desenvolvimento de sistema de gerenciamento de manutenção de extintores de incêndio. 2017. 83f. Dissertação (Mestrado em Engenharia Mecânica) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2017. | |
dc.identifier | https://repositorio.ufrn.br/jspui/handle/123456789/23783 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/3969628 | |
dc.description.abstract | Fire extinguishers are important equipment that help in the fight against fire. In order to maximize prevention and minimize impacts from possible accidents, extinguishers must meet valid recharge and must not have any type of malfunction or irregularity that may affect their performance during use. Currently most industries, shops, laboratories and others, do not have an efficient control of all fire extinguishers, as the use of manual spreadsheets is still used as a control. From the study carried out, it was characterized the need to create a system that could manage the maintenance of extinguishers as to: expiration of the recharges, validity of the hydrostatic test, irregularities found and that optimized the time of inspection. S.G.I software manages fire extinguisher maintenance, using Web and Mobile technologies associated with a geolocation database of fire extinguishers. The programming of the Web part was developed through the PHP language, using the free framework called CakePHP. As for the development of the mobile application, HTML5, CSS3 and JavaScript were used in a hybrid development environment, which allows the construction and use of the application for multi-platforms, without loss of performance for the user. To carry out the test of the developed system, the NUPLAM drug production laboratory located at the Federal University of Rio Grande do Norte (UFRN) was chosen because of the degree of risk that exists due to the handling of flammable compounds. | |
dc.publisher | Brasil | |
dc.publisher | UFRN | |
dc.publisher | PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA MECÂNICA | |
dc.rights | Acesso Aberto | |
dc.subject | Extintores de combate a incêndio | |
dc.subject | Gerenciamento da manutenção | |
dc.subject | WEB | |
dc.subject | Mobile | |
dc.title | Desenvolvimento de sistema de gerenciamento de manutenção de extintores de incêndio | |
dc.type | masterThesis | |