dc.contributorUniversidade de São Paulo (USP)
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Federal de São Carlos (UFSCar)
dc.contributorUniversidade Federal do Paraná (UFPR)
dc.date.accessioned2014-05-27T11:30:47Z
dc.date.accessioned2022-10-05T19:00:43Z
dc.date.available2014-05-27T11:30:47Z
dc.date.available2022-10-05T19:00:43Z
dc.date.created2014-05-27T11:30:47Z
dc.date.issued2013-10-01
dc.identifierMaterials Science and Engineering C, v. 33, n. 7, p. 4081-4085, 2013.
dc.identifier0928-4931
dc.identifierhttp://hdl.handle.net/11449/76726
dc.identifier10.1016/j.msec.2013.05.051
dc.identifierWOS:000325445700067
dc.identifier2-s2.0-84881159141
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3925604
dc.description.abstractThe preparation and electrochemical characterization of a carbon paste electrode modified with the N,N-ethylene-bis(salicyllideneiminato)oxovanadium (IV) complex ([VO(salen)]) as well as its application for ranitidine determination are described. The electrochemical behavior of the modified electrode for the electroreduction of ranitidine was investigated using cyclic voltammetry, and analytical curves were obtained for ranitidine using linear sweep voltammetry (LSV) under optimized conditions. The best voltammetric response was obtained for an electrode composition of 20% (m/m) [VO(salen)] in the paste, 0.10 mol L- 1 of KCl solution (pH 5.5 adjusted with HCl) as supporting electrolyte and scan rate of 25 mV s- 1. A sensitive linear voltammetric response for ranitidine was obtained in the concentration range from 9.9 × 10- 5 to 1.0 × 10- 3 mol L- 1, with a detection limit of 6.6 × 10- 5 mol L- 1 using linear sweep voltammetry. These results demonstrated the viability of this modified electrode as a sensor for determination, quality control and routine analysis of ranitidine in pharmaceutical formulations. © 2013 Published by Elsevier B.V.
dc.languageeng
dc.relationMaterials Science and Engineering C
dc.relation5.080
dc.relation1,110
dc.rightsAcesso restrito
dc.sourceScopus
dc.subjectElectrochemical sensor
dc.subjectModified carbon paste electrode
dc.subjectOxovanadium (IV) complex of salen
dc.subjectRanitidine
dc.subjectElectrochemical behaviors
dc.subjectElectrochemical characterizations
dc.subjectLinear sweep voltammetry
dc.subjectOxovanadium complexes
dc.subjectPharmaceutical formulation
dc.subjectSupporting electrolyte
dc.subjectCarbon
dc.subjectCurve fitting
dc.subjectCyclic voltammetry
dc.subjectElectrochemical sensors
dc.subjectElectrolytic reduction
dc.subjectEthylene
dc.subjectElectrochemical electrodes
dc.titleElectrochemical sensor for ranitidine determination based on carbon paste electrode modified with oxovanadium (IV) salen complex
dc.typeArtigo


Este ítem pertenece a la siguiente institución