dc.contributor | University of Florence | |
dc.contributor | Universidade Estadual Paulista (Unesp) | |
dc.contributor | CNR-IDASC | |
dc.date.accessioned | 2014-05-27T11:27:29Z | |
dc.date.accessioned | 2022-10-05T18:40:54Z | |
dc.date.available | 2014-05-27T11:27:29Z | |
dc.date.available | 2022-10-05T18:40:54Z | |
dc.date.created | 2014-05-27T11:27:29Z | |
dc.date.issued | 2013-01-01 | |
dc.identifier | Sensors and Actuators, B: Chemical, v. 179, p. 194-200. | |
dc.identifier | 0925-4005 | |
dc.identifier | http://hdl.handle.net/11449/74197 | |
dc.identifier | 10.1016/j.snb.2012.10.017 | |
dc.identifier | WOS:000316588100024 | |
dc.identifier | 2-s2.0-84880921300 | |
dc.identifier | 1923726000036625 | |
dc.identifier.uri | http://repositorioslatinoamericanos.uchile.cl/handle/2250/3923161 | |
dc.description.abstract | This paper describes the optimisation and the analytical performances of a label-free impedimetric immunosensor for the detection of tumour marker CA125 based on gold nanoparticles modified screen-printed graphite electrode. Experimental conditions of each step for the developed immunosensor were studied and optimised. The immunosensor response varied linearly (r2 = 0.996) with antigen concentration between 0 and 100 U/mL. The estimated detection limit was 6.7 U/mL. The electrochemical immunosensor allowed unambiguous identification of CA125, while no significant non-specific signal was detected in the case of all negative controls. The analytical usefulness of the impedimetric immunosensor was finally demonstrated analysing serum samples. © 2012 Elsevier B.V. All rights reserved. | |
dc.language | eng | |
dc.relation | Sensors and Actuators B: Chemical | |
dc.relation | 5.667 | |
dc.relation | 1,406 | |
dc.rights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | CA125 | |
dc.subject | Gold nanoparticles | |
dc.subject | Impedimetric immunosensor | |
dc.subject | Screen-printed electrode | |
dc.subject | Tumour marker | |
dc.subject | Analytical performance | |
dc.subject | Detection limits | |
dc.subject | Electrochemical immunosensors | |
dc.subject | Experimental conditions | |
dc.subject | Gold Nanoparticles | |
dc.subject | Impedimetric immunosensors | |
dc.subject | Screen printed electrodes | |
dc.subject | Gold | |
dc.subject | Graphite electrodes | |
dc.subject | Metal nanoparticles | |
dc.subject | Tumors | |
dc.subject | Immunosensors | |
dc.title | New label free CA125 detection based on gold nanostructured screen-printed electrode | |
dc.type | Artigo | |