dc.contributorUniversidade Estadual de Maringá (UEM)
dc.contributorUniversidade Federal de Goiás (UFG)
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:31:11Z
dc.date.accessioned2022-10-05T17:03:19Z
dc.date.available2014-05-20T15:31:11Z
dc.date.available2022-10-05T17:03:19Z
dc.date.created2014-05-20T15:31:11Z
dc.date.issued2009-04-01
dc.identifierJournal of Oral and Maxillofacial Surgery. Philadelphia: W B Saunders Co-elsevier Inc, v. 67, n. 4, p. 738-743, 2009.
dc.identifier0278-2391
dc.identifierhttp://hdl.handle.net/11449/40386
dc.identifier10.1016/j.joms.2008.06.034
dc.identifierWOS:000264808500004
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3911377
dc.description.abstractPurpose: The objective of this study was to carry out a comparative evaluation of the mechanical resistance of 2 rigid internal fixation techniques for fractures of the mandibular condyle using miniplates.Materials and Methods: Fort), polyurethane resin replicas of human hemimandibles were used. The hemimandibles were sectioned to simulate a high subcondylar fracture and then stabilized with 2 fixing techniques using 2.0-mm system plates and screws. The fixation techniques were 2 separate 4-hole plates with 8 screws, and 2 overlaid 4-hole plates with 4 screws. Each system was submitted to load tests, with the application of the load in mediolateral and anteroposterior directions in an Instron 4411 universal assay machine (Instron, Norwood, MA).Results: Load values and peak displacement were measured. Means and standard deviations were evaluated by analysis of variance (P < .05) and Tukey tests, in which it was verified that the anteroposterior peak load value was affected by the arrangement of the plates on the models, although no differences were observed between the groups for the mediolateral peak load. The arrangement of the plates did not have any influence on peak displacement. Similarly, the final value of the mediolateral load was not affected by the arrangement of the plates on the model.Conclusion: The experimental model with 2 separate plates was statistically superior to the model with 2 overlaid plates only in relation to anteroposterior peak load. Despite showing superiority in mediolateral peak load and peak displacement, there was no statistical difference between the groups for these parameters. (C) 2009 American Association of Oral and Maxillofacial Surgeons
dc.languageeng
dc.publisherW B Saunders Co-elsevier Inc
dc.relationJournal of Oral and Maxillofacial Surgery
dc.relation1.779
dc.relation0,967
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.titleComparative Study of the Mechanical Resistance of 2 Separate Plates and 2 Overlaid Plates Used in the Fixation of the Mandibular Condyle: An In Vitro Study
dc.typeArtigo


Este ítem pertenece a la siguiente institución