dc.contributorUniv Fortaleza
dc.contributorUniversidade Estadual Paulista (Unesp)
dc.contributorUniversidade Estadual de Ponta Grossa (UEPG)
dc.date.accessioned2014-05-20T13:46:35Z
dc.date.accessioned2022-10-05T14:14:28Z
dc.date.available2014-05-20T13:46:35Z
dc.date.available2022-10-05T14:14:28Z
dc.date.created2014-05-20T13:46:35Z
dc.date.issued2009-03-01
dc.identifierGerodontology. Malden: Wiley-blackwell Publishing, Inc, v. 26, n. 1, p. 65-71, 2009.
dc.identifier0734-0664
dc.identifierhttp://hdl.handle.net/11449/16501
dc.identifier10.1111/j.1741-2358.2008.00251.x
dc.identifierWOS:000263756500011
dc.identifier5737127334248549
dc.identifier3003130522427820
dc.identifier8000248781842587
dc.identifier8867670539105403
dc.identifier0000-0002-7375-4714
dc.identifier.urihttp://repositorioslatinoamericanos.uchile.cl/handle/2250/3891498
dc.description.abstractMicrowave energy has proved to be an effective method for disinfecting acrylic dentures. However, the effect of microwave heating on the porosity of autopolymerising denture reline resins has not been investigated.The purpose of the study was to determine the effect of microwave disinfection on the porosity of autopolymerised denture reline materials (Kooliner-K, New Truliner-NT, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and a conventional heat-polymerised denture base resin (Lucitone 550-L).Specimens (10 mm x 20 mm x 1 mm) were obtained from the impression surface of the palatal mucosa in a single person and divided into four groups (n = 5). The porosity was evaluated after polymerisation (C1), after two cycles of microwave disinfection (MW2), after seven cycles of microwave disinfection (MW7) and after 7 days storage in water at 37 degrees C (C2). Specimens from group MW7 were exposed to microwave disinfection daily being stored in water at 37 degrees C between exposures. All the replicas were sputter coated with gold and micrographs/digital images were taken of each replica using scanning electron microscopy at magnification x 100. The SEM micrographs were then examined using an image analyser to determine the number of pores. Comparison between materials and groups were made using Kruskal-Wallis tests.MW7 resulted in a significant increase in the number from the pores of material K, but decreased in number in reline material TR and UGH reline resin. The number of pores in materials NT and L remained unaffected following microwave disinfection.Differences in the porosity amongst the materials and for different experimental conditions were observed following microwave disinfection.
dc.languageeng
dc.publisherWiley-Blackwell Publishing, Inc
dc.relationGerodontology
dc.relation1.439
dc.relation0,627
dc.rightsAcesso restrito
dc.sourceWeb of Science
dc.subjectacrylic resins
dc.subjectrelining
dc.subjectporosity
dc.subjectmicrowave
dc.titleThe occurrence of porosity in reline acrylic resins. Effect of microwave disinfection
dc.typeArtigo


Este ítem pertenece a la siguiente institución